Leave the levelling tool in the storage drawer, so
that the customer can use it if they wish to move the
cooker.
Fitting a stability bracket
A stability bracket or chain (not supplied by with
the cooker) should be fitted when the cooker is
connected to a flexible gas supply.
When fitting a stability bracket read these
instructions together with the leaflet supplied with
the bracket.
1. Place the cooker in its intended position and level
the cooker.
2. Draw a pencil line 100mm from the front edge of
the levelling feet.
3. Mark the centre line for the bracket by measuring
550mm from the left hand side of the cooker.
4. Lower the front roller and move the cooker
forward.
5. Measure back from the pencil line 550mm to
locate the front edge of the bracket. Fix the
bracket to the floor.
6. Measure the height from floor level to
engagement edge in back of cooker. Add 3mm to
this dimension and assemble the stability bracket
to this height. (i.e. from floor level to underside
of the top member) and ensure the bracket does
not foul the oven burner assembly.
Check the appliance is electrically safe and gas sound when you have finished.
INSTALLATION
Gas Connection
Must be in accordance with the relevant standards. A
hose is not supplied by with the cooker. Hoses may
be purchased at most builders' merchants.
The Gas supply needs to terminate with a down
facing bayonet. The rear cover boxes limit the
position of the supply point.
View from the rear; A - position for gas supply connector, B - appliance
Because the height of the cooker can be adjusted
and each connection is different it is difficult to give
precise dimensions. Ideally the house supply bayonet
should be in the shaded area shown in the diagram.
The hose should be fitted so that both inlet and
outlet connections are vertical so that the hose hangs
downwards.
The hose should be fitted so that both inlet and
outlet connections are vertical so that the hose hangs
downwards in a 'U' shape.
In the UK:
For Natural Gas the flexible hose must be in
accordance with B.S.669.
For LP Gas it should be capable of 50mbar pressure,
70C temperature rise and carry a red stripe, band or
label.
Although a 900mm hose can be used, a 1250mm
hose will allow slightly more flexibility in the
positioning of the bayonet and make moving the
cooker easier. If in doubt contact, your supplier.
In the Republic of Ireland:
Consult I.S. 813 for details of connection
requirements.
Screw connect the threaded end of the hose into the
gas inlet in the underside of the connector block on
the back of the cooker.