Problem
Pump output low on both strokes.
Pump output low on only one stroke.
No output.
Pump operates erratically.
Pump will not operate.
12
Cause
Restricted air supply lines.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Worn piston packing.
Held open or worn ball check valves.
Worn piston packings.
Improperly installed ball check valves.
Exhausted fluid supply.
Held open or worn ball check valves.
Worn piston packing.
Restricted air supply lines.
Exhausted fluid supply.
Clogged fluid outlet line, valves, etc.
Damaged air motor.
Fluid dried on piston rod.
Solution
Clear any obstructions; be sure all shutoff
valves are open; increase pressure, but
do not exceed maximum working pres-
sure.
Refill and reprime pump.
Clear.
Replace. See lower manual.
Check and repair.
Replace. See lower manual.
Check and repair.
Refill and reprime pump.
Check and repair.
Replace. See lower manual.
Clear any obstructions; be sure all shut
off valves are open; increase pressure,
but do not exceed maximum working
pressure.
Refill and reprime pump.
Clear.
See air motor manual.
Disassemble and clean pump. See lower
manual. In future, stop pump at bottom of
stroke.
3A3383D