INSTALLATION

Regulations and Standards
In your own interest of safety, gas appliances should be installed by competent persons.
Failure to install the appliance correctly could invalidate any warranty or liability claims.
This appliance shall be installed in accordance with the manufacturer's installation
instructions, local gas fitting regulations, municipal building codes, AG5601 and any other
relevant statutory regulations.
Data label.
The data label is located on the right hand side front of the oven compartment, behind the
oven door. A duplicate data label is supplied to adhere to an accessible area next to the
appliance. Ensure that the gas supply is Universal LPG. This appliance is designed for
use with Universal LPG and should not be converted for use with any other gas.
Ventilation
This appliance is suitable for installation into Holiday Homes, Touring Caravans and Boats.
In all cases the national standards with regard to ventilation for the particular vehicle into
which the appliance is to be installed must be adhered to.
The installation must include adequate provision to avoid the accumulation of un-burnt
gases. We recommend a low level vent, discharging to the outside, Size 130mm
3850mm
2
Max - see Figs. 3 & 4.
Location of Appliance
This appliance maybe installed in a kitchen/kitchen diner but NOT in a room containing a
bath or a shower. LP gas appliances must not be fitted below ground level. e.g. in a
basement.
Position
The appliance must be installed in such a way that the furniture fitted around the unit
follows the minimum dimensions detailed within these instructions for either Low level
installation (Fig. 3) or High level installation (Fig. 4)
All cooking appliances become hot during use, it is important the installer verifies the
furniture construction material and that it is suitable for the application - i.e. plastic
materials used in the construction may have a softening point lower than the maximum
allowable temperature rise specified in the Australian Standard AS5601.
ALL combustible materials such as curtains and shelves must be kept well clear of the
appliance, and their installation should meet all relevant local and national standards in
force.
IMPORTANT
• This appliance must be installed into an aperture, sealed off at either side
in order to prevent draughts from adjoining cupboards/vents. Ensure that
air vents and gas escape holes are kept clear, holes for cables and pipes
must be sized to minimize air leakage between compartments.
• Under no circumstances should the ventilation hole exceed 3850mm
other low level ventilation located in the compartment, including vents in
kickboards. Low level vents in adjacent compartments are permitted.
Cupboards beneath the appliance MUST be sealed to prevent a gas
escape entering the living area.