Installation location
• The machine must be set up so as to allow good visual access.
• The device must be placed and leveled on a horizontal, sturdy,
water-resistant, and heatproof base.
• The device must not be cleaned using a water jet. The device
must be installed where it is protected against water spray.
• The device must not be located on a surface that is sprayed or
cleaned with a water hose, steam jets, steam cleaner, or similar
devices.
Water supply
On site:
• ½" (TW12) with main shutoff valve and dirt filter (250  µ m)
• Min. 0.36 MPa (3.6 bar) supply pressure at 6 l/min
Note
To ensure proper function of the
setting routine for the pressure
reducer, the minimum required
pre-pressure across the machine
connection is 2.4 bar (at 6 l/min).
At lower pressure, the pressure
difference will not be sufficient to
adjust the pressure reducer to the
set value.
This takes the normal pressure losses via water supply set and water
(1
filter into account. As a result, the flow pressure of 0.2 MPa (2 bar)
at 6 l/min required by the machine for maximum hourly output
will be ensured.
User Manual WMF 9000 F VB
Safety
(1
NOTE
15