Download Print this page

Q-tran QOM-eLED+DMX Installation Instructions Manual page 7

Hide thumbs Also See for QOM-eLED+DMX:

Advertisement

CSA REQUIREMENTS
● Suitable for Indoor and Outdoor use
● This power supply must be installed according to the National Electric Code and local codes and ordinances and in accordance with applicable installation
code by a person familiar with the construction and operation of the product and the hazards involved.
● Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
● This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
● To avoid a hazard to children, account for all parts and destroy all packaging materials.
● DMX Shield wire must be grounded
QOM-eLED
Model
QOM-eLED-60
QOM-eLED-120
QOM-eLED-180
QOM-eLED-100
QOM-eLED-200
QOM-eLED-300
● Suitable For Indoor Or Outdoor Use
● Wall Mount Only
INSTALLATION MURALE SEULEMENT
● Suitable For Mounting Within 1.2m (4ft) Of The Ground
PEUT ÊTRE INSTALLÉ À MOINS DE 1.2 M (4 PI) DU SOL
● Suitable For Use With Submersible Luminaires
Or Submersible Pumps
● Suitable For Wet Locations
CONVIENT AUX EMPLACEMENTS MOUILLÉ
● This Control Unit Has More Than One Power Supply Point
Disconnect All Power Supplies Before Servicing
COUPER L'ALIMENTATION AVEN L"ENTRETIEN
● For Supply Connections Use Wire Rated For At Least 60C.
● Keep Enclosure Cover Closed
● Read Installation Instructions Before Wiring
● Class 2
QOM-eLED
Model
QOM-eLED- 60
QOM-eLED-120
QOM-eLED-180
QOM-eLED-100
QOM-eLED-200
QOM-eLED-300
● Suitable For Indoor Or Outdoor Use
● Wall Mount Only
● Suitable For Mounting Within 1.2m (4ft) Of The Ground
● Suitable For Use With Submersible Luminaires
Or Submersible Pumps
● Suitable For Wet Locations
● This Control Unit Has More Than One Power Supply Point
Disconnect All Power Supplies Before Servicing
● For Supply Connections Use Wire Rated For At Least 60C.
● Keep Enclosure Cover Closed
● Read Installation Instructions Before Wiring
● Class 2
© 2019, Q-Tran Inc. 155 Hill St. Milford, CT 06460. All rights reserved - 203-367-8777 - sales@q-tran.com - www.q-tran.com
QOM - eLED+DMX
CSA Label
to Earth Ground at a single point external to Power Supply
INPUT VOLTAGE
Input Voltage
Input Current
(V)
(A)
120
0.60
120
1.20
120
1.80
120
0.95
120
1.90
120
2.85
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
CE PRODUIT DOIT ÊTRE INSTALLÉ SELON LE CODE D'INSTALLATION
PERTINENT, PAR UNE PERSONNE QUI CONNAÎT BIEN LE PRODUIT ET
SON FONCTIONNEMENT AINSI QUE LES RISQUES INHÉRENTS.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH
A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED.
CONSULT A QUALIFIED ELECTRICIAN
INPUT VOLTAGE
120V - 277V
Input Voltage
Input Current
(V)
(A)
120 / 277
0.60 / 0.29
120 / 277
1.20 / 0.58
120 / 277
1.80 / 0.87
120 / 277
0.95 / 0.40
120 / 277
1.90 / 0.80
120 / 277
2.85 / 1.20
This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
WARNING:
RISK OF FIRE. IF INSTALLATION INVOLVES RUNNING WIRE THROUGH
A BUILDING STRUCTURE, SPECIAL WIRING METHODS ARE NEEDED.
CONSULT A QUALIFIED ELECTRICIAN
OUTPUT VOLTAGE
120V
12V
Nominal Output
Frequency
Nominal Output
Voltage (VDC)
50/60
12
50/60
12
50/60
12
50/60
24
50/60
24
50/60
24
OUTPUT VOLTAGE
12V
Nominal Output
Nominal Output
Frequency
Voltage (VDC)
12
50/60
50/60
12
50/60
12
50/60
24
50/60
24
50/60
24
CONTROL TYPE
24V
0-10V
DMX
Wattage (W)
60
120
WD
180
100
AW
200
300
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM &
LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3425 - 15
3425 - 95
3402 - 15
3402 - 95
CONTROL TYPE
24V
0-10V
DMX
Wattage (W)
60
120
WD
180
100
AW
200
300
Q-TRAN, INC.
MILFORD, CT U.S.A.
(203) 367-8777
WWW.Q-TRAN.COM
LOW VOLTAGE LIGHTING SYSTEM &
LED LANDSCAPE LIGHTING SYSTEM
CLASS: 3425 - 15
3425 - 95
3402 - 15
3402 - 95
6

Advertisement

loading

This manual is also suitable for:

Qom-eled-60Qom-eled-120Qom-eled-180Qom-eled-100Qom-eled-200Qom-eled-300