Maintenance – Annually
Fig. 73
A View from below: Alignment of
filter during installation
Fig. 74
Fig. 75
Fig. 76
88
8.
Check the O-ring (2) for damage, replace if necessary.
9.
Install the filter (1).
Observe the alignment (A) of the filter on the housing.
10.
Assemble the filter bowl (3) with the O-ring.
11.
Unscrew the hexagon nuts (2) and the hexagon screw (1)
and take off the fuel tank.
12.
Loosen the hose clamp (1) and pull off the fuel hose.
13.
Unscrew the fuel strainer (3) with the seal (2).
14.
Clean the fuel strainer, check the condition of the screen,
replace if necessary.
15.
Turn the fuel strainer tightly in with the new seal.
16.
Assemble the fuel hose with the hose clamp.
17.
Assemble the fuel tank with hexagon nuts (2) and hexagon
screw (1).
18.
Check the fuel system for leaks.
19.
Dispose of fuel and replaced components in an environmen-
tally friendly way.