Service Manual
Step
8.
Remove motor and motor support
motor and disconnect the leading wire
insert of the motor. Then remove the
motor.
motor support and lift the motor support to
remove it.
9.
Remove Electric Box Assy
subassembly; loosen the wire bundle and
unplug the wiring terminals. Then lift the
electric box to remove it.
10.
Remove isolation sheet
sheet and then remove the isolation
sheet.
11.
Remove compressor
Unsolder the welding joint connecting the
capillary, valves and the outlet pipe of
condenser to remove the capillary. Do not
a
block the capillary with welding slag
during unsoldering.
Installation and Maintenance
Procedure
motor support
motor
isolation sheet
electric Box Assy
liquid valve
gas valve
83