Steps
8. Remove 4-way valve assy
Unsolder the spot weld of 4-way valve assy,
compressor and condenser, and then remove
the 4-way valve assy .
Note:
When unsoldering the spot weld, wrap the
4-way valve with wet cloth completely to avoid
damaging the valve due to high temperature.
9. Remove motor
Remove the screws fixing motor and then
remove the motor.
10. Remove motor support
Remove the screws fixing motor support and
then remove the motor support.
78
Procedure
Screws
Screws
Service Manual
4-way valve assy
Spot weld
Motor
Motor support