INSTALLATION INSTRUCTIONS FOR HeatFlo™ Kit
FOR USE IN ASTRIA ALLUMEDLX60TEN, ALLUME60TEN AND SUPERIOR DRL4060TEN FIREPLACES
(This Kit is Compatible for One Sided or See-Thru Application)
INSTALLER: Leave this manual with the fireplace.
CONSUMER: Retain this manual for future
reference.
IMPORTANT NOTICE
HTFLO-LIN60 (HeatFlo) KIT IS REQUIRED IF INSTALLING A
TV ABOVE THE FIREPLACE.
f i r e - p a r t s . c o m
WARNING
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of the
fireplace installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the fireplace.
TOOLS REQUIRED (not included)
Electric Drill/Driver Gun
Phillips Screwdriver Bits
5/16 Nut Driver
3/8 Nut Driver
Wood Screws
Kit Components
1 ea. Heat Register
1 ea. HeatFlo Register Trim
4 ea. 5" x 26" (compressed length) Flex Pipe
8 ea. Gear Clamp
4 ea. HeatFlo Collar
2 ea. Plenum Bracket
32 ea. Self Tapping Screws
900929-00 REV. B 05/2019
Catalog
Number
F3780
Flex Pipe
5" x 26"
Gear
Clamp
HeatFlo
Collar
GENERAL INFORMATION
The HeatFlo™ system is designed to redirect the convective heat
of the fireplace from the front of the unit, above the glass, to a
location higher on the wall. The use of this kit allows for TV instal-
lations closer to the fireplace or in recessed wall cavities above
the fireplace (see tables 1 and 2 on page 2).
When Installing this kit, reference the framing dimensions and
follow the framing instructions shown on the fireplace installation
Instructions. Follow all other installation requirements for the
fireplace as detailed in the installation manual.
REFER TO INSTALLATION INSTRUCTIONS AND CARE AND
OPERATIONS MANUAL (IICO) FOR FRAMING DETAILS BEFORE
INSTALLING THIS KIT.
ALL WARNINGS AND PRECAUTIONS IN THE INSTALLATION AND
OPERATION MANUAL PROVIDED WITH THE FIREPLACE APPLY
TO THESE INSTRUCTIONS.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
HEARTH PRODUCTS
KITS AND ACCESSORIES
HeatFlo™ Kit
Model Number
HTFLO-LIN60
HeatFlo
Register
Trim
Plenum
Bracket
HeatFlo™ Kit
Kit Name
HeatFlo Kit
Heat
Register
1

Advertisement

loading

Summary of Contents for IHP HeatFlo Kit HTFLO-LIN60

  • Page 1 HEARTH PRODUCTS KITS AND ACCESSORIES 900929-00 REV. B 05/2019 HeatFlo™ Kit INSTALLATION INSTRUCTIONS FOR HeatFlo™ Kit FOR USE IN ASTRIA ALLUMEDLX60TEN, ALLUME60TEN AND SUPERIOR DRL4060TEN FIREPLACES (This Kit is Compatible for One Sided or See-Thru Application) HeatFlo™ Kit INSTALLER: Leave this manual with the fireplace. Catalog Model Number Kit Name...
  • Page 2: Important Notice

    18" for a recessed installation, to reduce the amount of heat that reaches the television. The homeowner must understand that IHP does not take responsibility for any negative impact to televisions placed near this fireplace.
  • Page 3 HEATFLO™ KIT INSTALLATION Upper Front Face Barrier NOTICE Channel This kit must be installed by a qualified installer, Bottom Front service agency, or gas supplier at the time of the Face Barrier fireplace installation. These instructions must Channel be used in conjunction with the installation and DOWN operation manual provided with the fireplace.
  • Page 4 FIREPLACE PREPARATION Remove Fireboard Nailing Flange Top Prepare the fireplace for installation into the framing by removing Spacers for Recessed Installation the four HeatFlo diverter plate covers from underneath of fireplace top, discard HeatFlo diverter plate covers. Remove Fireboard Remove/discard the four HeatFlo outlet cover plates from Nailing Flange fireplace top by removing 4 screws on each outlet cover plate, for recessed...
  • Page 5 6” 3-1/2” 1” Clearance Fireplace Spacers 1” Min. Clearance To Combustibles All Around Pipes Secure Nailing flanges to Note: Support straps need to be oriented vertically or angled at 45° Jack Stud (Purpose is to support the register weight). Metal Straps both sides (not Figure 7 - Framing for Recessed Wall Pocket and HeatFlo Kit provided)
  • Page 6 With fireplace and heat register in place, attach the approved flex pipes (supplied with kit) to each of the collars on the fireplace top and secure them with gear clamps and 3 self tapping HeatFlo screws per collar (provided with kit) see Figure 9. Note: DO Register NOT SLICE PIPES! 3/8”...
  • Page 7 Re-Installing the Glass Door and Barrier NOTE: The HeatFlo Register Trim ships from the factory painted black and it may be painted another color to match the wall color; using high temperature paint rated for minimum 250°F continuous 1. Retrieve the glass door. Visually inspect the gasket on the rating(Figure 13).
  • Page 8 - p a r t s . c o m IHP.us.com Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.