3. Operation
3.11.3 Taking a product sample for calibration from the Auxillary Display
Before starting the calibration procedure:
The meter roll must be primed with product before
calibrating the meter.
Procedure:
1. Hang Calibration Bag (1) under meter being
calibrated (Fig. 24)
2. Enter the Rate Calibration Menu;
a. Use arrow pad to navigate.
b. Press "ok" to enter menu.
3. Select the product using the left and right
arrow keys (1).
a. Note the Current Calibration should
match what was entered into the
terminal in the cab.
4. Select CALIBRATE using the rightmost
button.
5. A Warning screen will appear;
a. PLEASE READ THIS WARNING
b. Press "ok".
Fig. 24
Fig. 25
Fig. 26
Fig. 27