Minuteman C82904-07 Operation Service Parts Care

Minuteman C82904-07 Operation Service Parts Care

Micro vacuum

Advertisement

Quick Links

Micro
Model: C82904-07
Vacuum
OPERATION
SERVICE
PARTS
CARE

Advertisement

Table of Contents
loading

Summary of Contents for Minuteman C82904-07

  • Page 1 Micro Model: C82904-07 Vacuum OPERATION SERVICE PARTS CARE...
  • Page 2 FOR COMMERCIAL USE ONLY IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, basic precautions should always be followed, including the following: READ ALL INSTRUCTIONS BEFORE USING WARNING - To reduce the risk of fire, electric shock, or injury: • Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
  • Page 3: Electrical - 115 Volt

    INSPECTION Carefully unpack and inspect your machine for shipping damage. Each unit is tested and thoroughly inspected before shipment, and any damage is the responsibility of the delivery carrier who should be notified immediately. ELECTRICAL - 115 Volt This machine is designed to operate on a standard 15 amp. 115 volt, 60 hz, AC circuit. Voltages below 105 volts AC or above 125 volts AC could cause serious damage to the motor.
  • Page 4: User Maintenance Instructions

    WARNING This vacuum may contain potentially hazardous dust depending on its application. Special handling of contaminated disposal bags and filters is recommended. Disposal must be in compliance with local EPA regulations USER MAINTENANCE INSTRUCTIONS All service and repair should be performed by qualified vacuum service representative or electri- cian.
  • Page 5: Operation And Filter Care Instructions

    OPERATION AND FILTER CARE INSTRUCTIONS The Minuteman Critical Filter Vacuum has been specifically designed to clean up fibrous asbestos, mold, and lead dust of all types. Special filters reduce the incidence of airborne dust that would be createdby any other method of cleaning.
  • Page 6 Raised tab Latch...
  • Page 7: Procedure For Removing Contaminated Filters And For Cleaning Of Contaminated Tank

    PROCEDURE FOR REMOVING CONTAMINATED FILTERS AND FOR CLEANING OF CONTAMINATED TANK For the benefit of your health, you should always wear personal protective clothing and respiratory protection any time you are using or cleaning this vacuum. 1. Unplug machine from power source. 2.
  • Page 10 PARTS LIST ITEM PART NO. REQ'D DESCRIPTION 110025 FILTER, HEPA-MICROVAC 110027 PREFILTER SLEEVE, ALLERVAC - SINGLE 290017 MOLDED VAC MOTOR GASKET 290031 LID GASKET 294/6 DIECUT 290032 DOME SEAL 296 380001-4 MOTOR-VAC BYPASS 120V (ECM) W/ WIRES 740088 SWITCH-VAC LIGHT SENSOR 380064 RING, FOAM 381020...
  • Page 11: Parts List

    PARTS LIST ITEM PART NO. REQ'D DESCRIPTION 390087 GASKET DIECUT VNN 390110 INTAKE ASSEMBLY ALUMINUM 460111 TANK 4GAL LOW INTAKE 460114 LATCH POLY TNK 460115 DOLLY, PLAST VAC TNK BLK 460118 CASTER 711160 SCR-HI/LO #10 X 5/8 ZINC 712320 WSR .20 X .45 X .048 NYL 712638 NUT HEX 10-24 SS NYLOC 712824...
  • Page 12 Parts List ITEM PART NO. REQ'D DESCRIPTION 711909 RIVET-POP .19 X .44 AL 712764 WSR #10 SS 760244MCH PLASTIC BAG FRAME W/HOLE 805043 BAG ONLY 4G 829093 BAG FRAME 4G 390005 GASKET 4/6 GAL 1TO1 829094 BAG ASY COMP...
  • Page 13 Minuteman International, Inc. warrants to the original purchaser/user that the product is free from defects in workmanship and materials under normal use. Minuteman will, at its option, repair or replace without charge, parts that fail under normal use and service when operated and maintained in accordance with the applicable operation and instruction manuals. All warranty claims must be submitted through and approved by factory authorized repair stations.

Table of Contents