POSITIVE CRANKCASE VENTILATION (PCV) VALVE HEATER FITTING CONSTRUCTION/OPERATION [MZI-
3.5]
• Install on the dynamic chamber.
End Of Sie
NG: CHARCOAL CANISTER
CHARCOAL CANISTER FUNCTION [MZI-3.5]
• The charcoal canister contains activated charcoal that temporarily absorbs evaporative gas.
End Of Sie
CHARCOAL CANISTER CONSTRUCTION/OPERATION [MZI-3.5]
• During purge solenoid valve operation,
atmosphere enters the charcoal canister from the
atmospheric orifice to entirely flood the activated
charcoal and release the evaporative gas.
End Of Sie
NG: CANISTER VENT (CV) SOLENOID VALVE
CANISTER VENT (CV) SOLENOID VALVE FUNCTION [MZI-3.5]
• Seals the atmosphere side of the charcoal canister during EVAP leak check monitoring.
End Of Sie
CANISTER VENT (CV) SOLENOID VALVE CONSTRUCTION/OPERATION [MZI-3.5]
• Equipped to the evaporative hose between the
charcoal canister and air filter.
End Of Sie
NG: AIR FILTER (EMISSION SYSTEM)
AIR FILTER FUNCTION [MZI-3.5]
• The air filters dust from the air drawn to the charcoal canister.
End Of Sie
01-16–8
EMISSION SYSTEM [MZI-3.5]
TO ATMOSPHERE
PCV VALVE HEATER FITTING
TO PURGE SOLENOID VALVE
FROM FUEL TANK
CV SOLENOID VALVE
id0116d1105800
ac9uun00000064
id0116d1101900
id0116d1102000
ac9uun00000031
id0116d1190100
id0116d1190200
ac9uun00000052