Mazda CX-9 2007 Service Highlights page 399

Hide thumbs Also See for CX-9 2007:
Table of Contents

Advertisement

Two-step Down Function
• If a switch is lightly pushed (manual open operation) when the window is completely closed, the window lowers
a set distance. (Initial setting is approx. 30 mm {1.2 in}.)
• If the manual open operation is performed with the two-step down function enabled, the window will always stop
momentarily. (This is not a malfunction.)
• The set distance the window goes down can be changed. (Within a range of approx. 20-100 mm {0.79-3.9 in}.)
• The two-step down function can be disabled. (Initial setting is enabled)
• If the operation of the auto open/close, manual close or window obstruction is detected during two-step down
function operation, these other operations are given priority.
• Does not function during IG OFF Timer operation.
Ignition Off Timer Function
• Allows operation of the driver's power window for approx. 40 s after the ignition switch has been turned from the
ACC to the LOCK position.However, when the front door is opened/closed during IG OFF timer, the function
stops.
Fail-safe Function
• The power window system is switched to fail-safe mode to prevent a malfunction when the P/W CM detects a
malfunction in the pulse signal (Hall IC).
Detection condition
Hall effect switch 1 (for jam-safe and window position detection)
operation malfunction
• During up/down movement, Hall effect switch 2 pulse
detected but Hall effect switch 1 pulse not detected
Hall effect switch 2 (for window movement direction detection)
operation malfunction
• During up/down movement, Hall effect switch 1 pulse
detected but Hall effect switch 2 pulse not detected
Pulse signal malfunction detected (Inversion of input signals of or
large phase deviation between, Hall effect switch 1 and 2.)
• During up/down movement, difference detected between the
direction signals from Hall effect switches 1 and 2, and actual
direction
Non-return range downturn malfunction
• During up movement, the signal input from Hall effect switch 1
higher than the position stored in the P/W main switch
Hall effect switches 1 and 2 operation malfunction
• Hall effect switches 1 and 2 pulse signal not detected after
down movement initiated from the fully closed position
End Of Sie
GLASS/WINDOWS/MIRRORS
IG switch
Automatic
operation
prohibited
IG switch
ON
OFF
During up movement, pulse
Automatic
signals for Hall effect
and manual
switches 1 and 2 detected
operation
normally, and fully closed
prohibited
position return/non-return
Recovery items
09-12
ranges redetected
09-12–7

Advertisement

Table of Contents
loading

Table of Contents