6.2 Environment of use

The positioning of the stove is decisive for successful even heating of the room. Before deciding where to place the stove, the following must be
6.2 Environment of use
taken into account:
- The stove must be installed on a floor with a sufficient carrying capacity. If the existing building does not meet this requisite, appropriate measures
The positioning of the stove is decisive for a successfuland equal heating of the room. Before deciding where to place the stove, the following must be
must be taken (i.e. load distribution plate).
taken into account:
- The combustion air cannot be obtained from a garage or from an area without ventilation or exchange of air, but from a free or external space
- The stove must be installed on a floor with a sufficient carrying capacity. If the existing building does not meet this requisite, appropriate measures must
- The stove must not be installed in a bedroom, bathroom or shower, or where there is already another heating appliance without an autonomous
be taken (i.e. load distribution plate).
air flow (chimney, stove etc.)
- The combustion air cannot be obtained from a garage or from an area without ventilation or exchange of air, but from a free or external space
- A minimum of 3" inches from the rear of the stove, 3" inches from the side of the stove and 16" inches from the top of the stove must be maintained
- The stove must not be installed in a bedroom, bathroom or shower, or where there is already another heating appliance without an autonomous air flow
from combustible materials.
(chimney, stove etc.)
- A non-combustable Hearth board 6" from front of unit and 6" from the sides must be installed before unit is placed on the floor.
- A non-combustable Hearth board 6" from front of unit and 6" from the sides must be installed before unit is placed on the floor.
- Installation is better in a large and central room in the house to ensure maximum circulation of the heat;
- Installation is better in a large and central room in the house to ensure maximum circulation of the heat;
- Connection to the main supply is recommended using a grounded outlet (if the cable supplied is not long enough to reach the nearest outlet, use
- Connection to the main supply is recommended using a grounded outlet (if the cable supplied is not long enough to reach the nearest outlet, use an
an extension cord with a surge protector);
extension cord with a surge protector);
- The stove must be placed in a position that receives the necessary level of air for appropriate combustion of the pellets (at least 131.23 f
- The stove must be placed in a position that receives the necessary level of air for appropriate combustion of the pellets (at least 131.23 f
be available), in accordance with installation regulation and local legislations;
available), in accordance with installation regulation and local legislations;
- All joints for connector pipe is required to be fastened with at least three screws.
- All joints for connector pipe is required to be fastened with at least three screws.
- If vented horizontally joint should be siliconed with hi-temp. silicone and screwed so they are gas tight. (RTU 500 silicone)
- If vented horizontally joint should be siliconed with hi-temp. silicone and screwed so they are gas tight. (RTU 500 silicone)
- the chimney connector shall not pass through an attic or roof space, closet or similar conceald space, or a floor or ceiling. Where passage through
- the chimney connector shall not pass through an attic or roof space, closet or similar conceald space, or a floor or ceiling. Where passage through a
a wal, or partition of combustible construction is desired, the installationshall conform to CAN/CSA-B365.
wal, or partition of combustible construction is desired, the installationshall conform to CAN/CSA-B365.
The stove must be installed and assembled by qualified personnel.
The stove must be installed and assembled by qualified personnel.
The room must be:
The room must be:
- Prepared for the environmental functioning conditions
- Prepared for the environmental functioning conditions
- Prepared with an adequate system of evacuation of smoke
- Prepared with an adequate system of evacuation of smoke
- Have a 120V 60 Hz (EN73-23) electricity mains supply
- Have a 120V 60 Hz electricity mains supply
- Do not connect this unit to a chimney flue serving another appliance
- Do not connect this unit to a chimney flue serving another appliance
- Use only UL Listed Type L Vent or Pellet Vent 3" in. I.D. venting system to exhaust. Do not install flue damper in the exhaust system of this unit.
- Use only UL Listed Type L Vent or Pellet Vent 3" in. I.D. venting system to exhaust. Do not install flue damper in the exhaust system of this unit.
- The chimney connector and each other adjoining section must be firmly attached and secured to the stove.
- The chimney connector and each other adjoining section must be firmly attached and secured to the stove.

6.3 Mobile Home Requirements

6.3 Mobile Home Requirements
- Outside air is required
- Outside air is required
- The heater must be secured to the floor using lag bolts.
- The heater must be secured to the floor using lag bolts.
- The heater must be grounded to the chassis of the mobile home.
- The heater must be grounded to the chassis of the mobile home.
- Installation should be in accordance with the manufactured home.
- Installation should be in accordance with the manufactured home.
- When outside air is required, system parts, such as vent sections, supports, spark arresters, rodent screens, etc. must be used.
- When outside air is required, system parts, such as vent sections, supports, spark arresters, rodent screens, etc. must be used.
- The space heater is to be connected to a factory built chimney conforming to CAN/ULC-S629.
- The space heater is to be connected to a factory built chimney conforming to CAN/ULC-S629.
- It is important to use all the specified components, do not use other components.
- It is important to use all the specified components, do not use other components.
- Installation shall maintain an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the
- Installation shall maintain an effective vapour barrier at the location where the chimney or other component penetrates to the exterior of the structure.
structure.
-Operating the space heater with open firing doors can cause serious injuries and health damages due to excaping flames or carbon monoxide generation
-Operating the space heater with open firing doors can cause serious injuries and health damages due to excaping flames or carbon monoxide
inside the room.
generation inside the room.
- Adequate ventilation is required to avoid air starvation and icing which can determine an unhealthy indoor environment.
- Adequate ventilation is required to avoid air starvation and icing which can determine an unhealthy indoor environment.
- Do not overfire.
- Do not overfire.
- If the space heater is not correctly installed and operated it can interfere with smoke detectors.
- If the space heater is not correctly installed and operated it can interfere with smoke detectors.
A
A
Minimum 4' clearance below or beside any door or window that opens( with ooutside air insttalled, 1' below or beside)
Minimum 1' clearance below or beside any window that does not open.
B
B
Minimum 1' clearance above any door or window that opens
C
C
Minimum 2' clearance from any adjacent building
D
D
Minimum 7' clearance above any grade when adjacent to public walkways
E
E
Minimum 2' clearance above any grass, plants, or other combustible materials
F
F
Minimum 3' clearance from any forced air intake of any other appliance
G
G
Minimum 2' clearance below eaves or overhangs
H
H
Minimum 1' clearance horizontally from combustible wall
X
X
Must be a minimum of 2' above the roof
User and maintenance manual for stoves with RDS technology
User and maintenance manual for stoves with RDS technolo
Minimum 4' clearance below or beside any door or window that opens
Minimum 1' clearance below or beside any window that does not open.
Minimum 1' clearance above any door or window that opens
Minimum 2' clearance from any adjacent building
Minimum 7' clearance above any grade when adjacent to public walkways
Minimum 2' clearance above any grass, plants, or other combustible materials
Minimum 3' clearance from any forced air intake of any other appliance
Minimum 2' clearance below eaves or overhangs
Minimum 1' clearance horizontally from combustible wall
Must be a minimum of 2' above the roof
gy
WARNING: Do not install in bedroom
WARNING: Do not install in bedroom
CAUTION: The structural integrity of the mobile home floor,
CAUTION: The structural integrity of the mobile home floor,
ceiling, walls, roof must be maintained.
ceiling, walls, roof must be maintained.
Refer to HUD Requirements, CFR 3280, Part 24
Refer to HUD Requirements, CFR 3280, Part 24
NOTE: Install vent at clearances specified by the vent
NOTE: Install vent at clearances specified by the vent
manufactures.
manufactures.
NOTE: Measure clearances to the nearest edge of the exhaust
NOTE: Measure clearances to the nearest edge of the exhaust
hood.
hood.
NOTE: Vent may not terminate in covered walkway or breezeway.
NOTE: Vent may not terminate in covered walkway or breezeway.
NOTE: If venting horizontally, check your venting specifications
NOTE: If venting horizontally, check your venting specifications for
for distance pipe should extrude from building.
distance pipe should extrude from building.
01/02/2016
11/11/14
Pag.12
Pag.8