Ravelli Flexi 7 Use And Maintenance Manual

Ravelli Flexi 7 Use And Maintenance Manual

Pellet stove
Hide thumbs Also See for Flexi 7:
Table of Contents

Advertisement

Quick Links

Flexi 7
Flexi 9

Advertisement

Table of Contents
loading

Summary of Contents for Ravelli Flexi 7

  • Page 1 Flexi 7 Flexi 9...
  • Page 3 Marca / Trademark / Marque / Merk / Marke / Marca Ravelli Modello / Model / Modèle / Model / Modell / Modelo Flexi 7 Classe di efficienza energetica / Energy Efficiency class /Classe d’Efficacité Énergétique / Flexi 7 Energie-efficiëntieklasse / Energieeffizienzklasse / Clase de eficiencia energética...
  • Page 4 FICHA DEL PRODUTO EU 2015/1186 Marca / Trademark / Marque / Merk / Marke / Marca Ravelli Modello / Model / Modèle / Model / Modell / Modelo Flexi 9 Classe di efficienza energetica / Energy Efficiency class /Classe d’Efficacité Énergétique / Flexi 9 Energie-efficiëntieklasse / Energieeffizienzklasse / Clase de eficiencia energética...
  • Page 5 2. Type, batch or serial number or any other element allowing identification of the construction product as required under Art. 11(4): Flexi 7 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Residential space heating appliance fired by wood pellets 4.
  • Page 6 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Residential space heating appliance fired by wood pellets 4. Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5): Ravelli Aico S.p.A. Via A. Kupfer, 31 25036 Palazzolo s/O (Bs) Italia 5.
  • Page 7 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Residential space heating appliance fired by wood pellets 4. Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5): Ravelli Aico S.p.A. Via A. Kupfer, 31 25036 Palazzolo s/O (Bs) Italia 5.
  • Page 8 3. Intended use or uses of the construction product, in accordance with the applicable harmonised technical specification, as foreseen by the manufacturer: Residential space heating appliance fired by wood pellets 4. Name, registered trade name or registered trademark and contact address of the manufacturer as required by Art. 11 (5): Ravelli Aico S.p.A. Via A. Kupfer, 31 25036 Palazzolo s/O (Bs) Italia 5.
  • Page 9 Marchio Trademark Ravelli Marque Modello Model Flexi 7 Modèle L'oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione dell'Unione: The object of the declaration described above is in conformity with the relevant Union harmonisation legislation: L'objet de la déclaration décrit ci-dessus est conforme à l'harmonisation de l'Union concernant la législation la directive:...
  • Page 10 Pellet stove Product type Type de produit Poêle à granulés de bois Marchio Trademark Ravelli Marque Modello Model Flexi 9 Decò - Flexi Glass- Flexi Steel Modèle L'oggetto della dichiarazione di cui sopra è conforme alla pertinente normativa di armonizzazione...
  • Page 11: Table Of Contents

    Rev.0 18/05/2020 Use and maintenance manual Flexi 7 - Flexi 9 Pag.11 Sommario Preface......................................13 IDENTIFICATION ............................14 Stove identification ..................................14 Manufacturer identification .................................14 Reference standards ..................................14 WARRANTY ..............................15 Certificate of warranty..................................15 Warranty conditions ..................................15 Info and problems ..................................15 GENERAL INFORMATION ..........................16 Supply and safe-keeping ................................16...
  • Page 12 Rev.0 18/05/2020 Use and maintenance manual Flexi 7 - Flexi 9 Pag.12 MAINTENANCE ..................................53 Safety warnings for maintenance ...............................53 Cleaning .......................................53 Glass cleaning .....................................54 Combustion chamber cleaning ..............................54 To clean the pellet tank, proceed as follows: ..........................54 Extraordinary maintenance .................................54 Deep combustion chamber cleaning ............................54...
  • Page 13: Preface

    Incorrect installation, maintenance and improper use of the product relieve the Manufacturer of all liability deriving from use of the stove. For further information and requirements contact your Ravelli-authorised Technical Assistance Centre. All rights reserved. No part of this instructions manual can be reproduced or transmitted through any electronic or mechanical means, including photocopies, recordings or any other storage system, for other purposes that are not exclusively use by the buyer’s staff,...
  • Page 14: Identification

    Fax +39 030 7301758 www.ravelligroup.it info@ravelligroup.it Reference standards The Flexi 7 - Flexi 9 stoves that this manual refers to are compliant with the regulation: 305/2011 CONSTRUCTION PRODUCT REGULATION And observe the following harmonised standard: EN 14785; EN 55014-1; EN 55014-2; EN 61000-3-2; EN 61000-3-3; EN 60335-1; EN 60335-2-102; EN 62233; EN 50581; ETSI EN 300220-1 All local laws, including national and European standards, must be followed for the installation of the appliance.
  • Page 15: Warranty

    Use and maintenance manual S70 - S90 - SC90 Pag.15 WARRANTY Certificate of warranty Ravelli thanks you for the trust granted with the purchase of one of its products and invites the purchaser to: • read the installation, use and maintenance instructions for the product; •...
  • Page 16: General Information

    Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.16 GENERAL INFORMATION Supply and safe-keeping The manual is supplied in printed format. Keep this manual safe, with the stove, so that the user can consult it easily. The manual is an integral part, for safety reasons, therefore: •...
  • Page 17: Residual Risks

    If the chimney catches fire you must call the fire brigade. ⚠ Only use original spare parts. Any tampering and/or replacements that have not been authorised by Ravelli can pose a danger to the user’s safety. ⚠ In the event of particularly adverse weather conditions, the safety systems could intervene and switch off the stove.
  • Page 18: Reasonably Foreseeable Incorrect Use

    Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.18 The stove is designed and built to work safely if: • it is installed by qualified staff according to the specific standards; • it is used within the limits declared in the contract and herein; •...
  • Page 19: Forbidden Actions

    A2 and B. Maintain fuels and other flammables at a suitable distance. Ravelli recommends using wood pellet classified A1 and A2 according to the EN ISO 17225-2:2014 standard, or certified DIN PLUS (more restrictive than the A1 class) or ONORM M 7135. Pellet may be light or dark coloured, it is normally bagged into bags that show the name of the producer, the main characteristics and classification according to standards.
  • Page 20: Technical Characteristics

    The data shown here is provided as a guideline and is not binding, and may change based on what type and quality of wood is used. Ravelli reserves the right to make any changes in order to improve product performance.
  • Page 21: Measurements

    Rev.0 18/05/2020 Use and maintenance manual Flexi 7 - Flexi 9 Pag.21 Measurements Flexi 7 Flexi 9 Decò Flexi 9 Glass Flexi 9 Steel Unit of measurement Height 1050 1050 1050 1050 Width Depth Weight Technical diagram Flexi 7 50 (AIR INLET)
  • Page 22: Technical Diagram Flexi 9

    Rev.0 18/05/2020 Use and maintenance manual Flexi 7 - Flexi 9 Pag.22 Technical diagram Flexi 9 50 (AIR INLET) 80 (DUCTING) 72,5 80 (SMOKE OUTLET) CODICE COMPLETO CODICE CORPO 90012ER02-BCO 90012ER02 90012ER02-BLK 90012ER02 90012ER02-SIL 90012ER02 FORMATO SCALA MASSA TOLLERANZE GENERALI SECONDO LA CLASSE UNI EN 22768-mK...
  • Page 23: Main Parts

    Slide for ashes Reset thermostat Air passage gap Description of operation Ravelli pellet stoves of the Flexi 7 and Flexi 9 family are home heating appliances powered by wood pellets with automatic loading. They SE NON SPECIFICATO: FINITURA: INTERRUZIONE NON SCALARE DISEGNO...
  • Page 24: The Majolica Cladding (If Applicable)

    Rev.0 18/05/2020 Use and maintenance manual Flexi 7 - Flexi 9 Pag.24 The Majolica cladding (if applicable) The Majolica cladding is artisan-crafted and hand-finished. For this reason there may be minor imperfections on the surface such as slight discoloration and hair cracks, which are considered ⚠...
  • Page 25: Safety Warnings For Transportation And Installation

    Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.25 SHIPPING AND INSTALLATION Safety warnings for transportation and installation �� The stove must be installed by a qualified technician, who must issue a declaration of conformity of the system to the purchaser, taking full responsibility for stove installation and correct operation.
  • Page 26: Chimney

    Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.26 �� Be careful when building the smoke evacuation system and observe the regulations in force in the country where the stove ⚠ is installed. The Manufacturer will not be held liable for incorrectly sized and non-regulation smoke evacuation systems. Smoke ducts and fittings The term smoke duct indicates all ducts that connect the combustion equipment to the chimney.
  • Page 27: Requirements For The Installation Premises

    �� Ravelli shall not be held liable if these precautions are not followed. Requirements for the installation premises The stove installation room must be sufficiently ventilated. To fulfil this requisite it is necessary to equip the room with an air intake connected to the outdoors.
  • Page 28: Installation Example For A Stove/Pellet Stove

    Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.28 Installation example for a stove/pellet stove This type of installation (See Fig.1) requires an insulated chimney pot, even if the entire conduit is installed inside the building. Besides, the structure must be inserted into a properly ventilated skylight shaft.
  • Page 29 Rev.0 18/05/2020 Use and maintenance manual S70 - S90 - SC90 Pag.29 This type of installation (See Fig.4) requires an insulated Protection from rain chimney pot, even if the entire smoke conduit is installed outside the building. In the lower part of the chimney there is a "T" type fitting installed with inspection cap.
  • Page 30: Connections

    Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7-9 Pag.30 Connections �� The connections must be set up by a technician that is qualified and/or authorised by the Manufacturer. �� By the installer the type of cable, with relative section, to be installed in case of replacement is: H05RR-F sez.3G0,75 Connection with external air intake The stove has been designed for hermetic installations.
  • Page 31: Ducting

    Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7-9 Pag.31 ⚠ Recharge the fuel Use only wood pellets, the characteristics shown in this manual. ⚠ During pellet loading prevent the pellet bag from coming into contact with hot surfaces. To load the pellets inside the hopper, proceed as described below:...
  • Page 32: Electric Scheme Flexi 7-9

    G2- Conta colpi pulitore G1 -Extractor revolution extracteur G2 - Hubzähler automatischer G2 - Cuenta golpes limpiador au Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7-9 automatico reading encoder G2 – Compte coups nettoyeur Reiniger tomático Pag.32 G3 - Portátil “RADIO”...
  • Page 33: Controls And Use

    Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7-9 Pag.33 Controls and use Control panel description ON/OFF key; SETTING WORK POWER It is possible to use button 2 to change the delivered heat power.In order to increase power press P2 once again.
  • Page 34: Description Of The Handheld Set

    Handheld touch radio initialization The handheld, after a first short screen showing the Ravelli logo, will list the languages available in the menu. Select the desired language with the scroll buttons and confirm your selection with the confirmation button.
  • Page 35: Description Of The Display

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.35 In order to operate correctly, the handheld set should be interfaced with the electronic board installed inside the stove. For this reason, on display appears the following message: If the handheld set is used for the first time, select YES using the selection keys and confirm with the dedicated key. On the display of the handheld set appears the following: The flashing yellow LED indicates that the circuit board is waiting to receive the signal from the handheld set.
  • Page 36: Time And Date Setting

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.36 In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove. In the active phases, it indicates the operating power of the stove. In addition, by pressing the DOWN scroll button, you can display the power settings, that can be edited using the two scroll keys 2- Icon indicating the status of the stove (see synthetic phase diagrams).
  • Page 37: Checks Prior To Start-Up

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.37 Vers. 01 of:07.04.14 User’s manual HANDHELD TOUCH RADIO Pag.23 ⚠ PPROCEDURES FOR USE Operating phases of the appliance Modulation If the chimney catches fire you must call the fire brigade immediately. During the work phase, the appliance should reach the room temperature set;...
  • Page 38: Operating Phases Of The Appliance

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.38 Failed ignition ⚠ In models without a self-cleaning brazier, check that the brazier is empty and clean. ⚠ The brazier could be very hot: danger of burns! Never empty the brazier inside the hopper. Setting operating temperature and power: Set the two values following the indications given in the chapter “Description of thr display”...
  • Page 39 ⚠ Pag.30 necessary to modify the pellet parameter. optional kit from the retailer or the authorized Ravelli dealer. Stove State Stove State Combustion regulation is an operation that requires a lot of experience. We recommend that you contact an Authorised Layout 1 (DHW Boiler + heating control) Below are given the steps for accessing the relative menu starting from Stand-By mode.
  • Page 40 Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.40 Vers. 01 del 07/04/15 Manuale utente PALMARE IDRO TOUCH RADIO Pag.30 Stove state Stove State Below are given the steps for accessing the relative menu starting from “Home” mode. Below are given the steps for accessing the relative menu starting from Stand-By mode. MENU USER USER...
  • Page 41: Setting

    ENABLE COMFORT COMFORT CLIMA ENABLE COMFORT Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 ENABLE COMFORT Pag.41 RESTART DELTA SHUTDOWN DELAY COMFORT CLIMA COMFORT CLIMA DELTA COMFORT CLIMA DELTA In the inactive phases (combined with the 3rd part of the display) indicates the state of the stove. In the active phases, it indicates the operating power of the stove.
  • Page 42 “confirm” to “confirm” “confirm” to “selection” to switch “selection” to switch “confirm” access the to access the function access the to the function to the function to access the function SETUP CONTRAST. SETUP CONTRAST. Rev.0 18/05/2020 SETTINGS SETTINGS Manuale uso e manutenzione S70- S90- SC90 Use the UP/DOWN keys to change the WINTER/ Pag.42 Use the UP/DOWN keys to change the WINTER/...
  • Page 43: Single Ducting

    Rev.0 18/05/2020 Use and maintenance manual S70- S90- SC90 Page43 Single ducting This function allows you to manage distribution of warm air between the room where the stove is installed and the room where the duct arrives. The function has two operating modes: manual and automatic. Manual mode: the user manually sets distribution of warm air between front ventilation and ducting.
  • Page 44: Temperature (Automatic Mode)

    Rev.0 18/05/2020 Use and maintenance manual S70- S90- SC90 Page44 Temperature (automatic mode) Automatic mode: When this function is activated, the stove automatically manages the 5 ducting levels. To use automatic mode, two room temperature probes (optional) or external thermostats must be installed in the room to be ducted to set the temperature of the room served by ducting, or else reading of the thermostat must be enabled, following the steps below.
  • Page 45: Display Of Single Ducting Status

    Rev.0 18/05/2020 Use and maintenance manual S70- S90- SC90 Page45 Display of single ducting status The following are the steps to be followed to access the status display, starting from the “Home” screen. MENU USER DUCTED MANAGEMENT DUCTED USER TEMPERATURE FEED SCREW LOAD VENTILATION TECHNICIAN...
  • Page 46: Stove Phase General Layout

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.46 Stove phase general layout PHASE DESCRIPTION FINAL CLEANING The stove is in the switch off phase and the cooling phase has not been completed yet. SWITCH ON The heater pre-heating phase has started and the pellets start to fall into the grate.
  • Page 47 Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.47 ANOMALY (general) The stove has detected an anomaly; refer to the troubleshooting chapter. AUTOMATIC CLEANING For models with automatic cleaning system it indicates the SYSTEM ACTIVE operating state of the same. Warning Pop -Up ANOMALY DESCRIPTION...
  • Page 48 Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.48 AL 08 DEPRESSION The flue is blocked. Check the flue is free and clean The vacuum meter is faulty. Check the mains voltage. AL 12 FUME The fume exhaust system has a loss of Check the mains voltage.
  • Page 49: Installation Quick Guide Ravelli Smart Wi-Fi

    (ESEMPI A e B) ATTENZIONE! ATTENZIONE! Eseguire questa operazione esclusivamente ad apparecchio freddo Installation quick guide Ravelli Smart Wi-fi Eseguire questa operazione esclusivamente ad apparecchio freddo e con spina elettrica disinserita. Connect the WiFi module cable e con spina elettrica disinserita.
  • Page 50: Connection To The Wifi Network

    CONNECTION TO THE WiFi NETWORK Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.50 Click in succession > Networks. The Select wifi network screen will appear. Click Scan for networks: Connection to the WiFi network select your WiFi network and enter the password if required. Close the Click in succession >...
  • Page 51: Wifi Device Registration

    Deactivate the WiFi connection on your device, open the App and Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 click Access to cloud. Select Register your account, enter the required Pag.51 information (the name must not contain spaces) and click Register. Account registration Deactivate the WiFi connection on your device, open the App and click Access to cloud.
  • Page 52 Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.52 STEP 2 enter the product serial number and give the module a name living room stove); STEP 2 enter the product serial number and give the module a name (e.g. living room stove); STEP 3 complete with your information, click Next and then Comple STEP 3 complete with your information, click Next and then Complete registration.
  • Page 53: Maintenance

    Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7- Flexi 9 Pag.53 MAINTENANCE ⚠ Safety warnings for maintenance Maintenance of the stove must be performed at least once a year and should be planned in advance with the Technical ⚠ Assistance Service.
  • Page 54: Glass Cleaning

    Schedule the above extraordinary maintenance activities with the Authorised Assistance Centre. Deep combustion chamber cleaning �� This operation must be carried out by a Ravelli Assistance Centre. �� Schedule this type of cleaning with the Ravelli Assistance Centre. To clean the combustion chamber, proceed as described below: After cleaning the combustion chamber, it is advisable to proceed with the cleaning of the inspection hatches as indicated in the para- graph “Smoke duct cleaning”.
  • Page 55: Checking The Seals

    PESO: SCALA:1:5 FOGLIO 1 DI 1 Checking the seals �� This operation must be carried out by a Ravelli Service Centre. Plan this type of cleaning with the Ravelli Service Centre. SE NON SPECIFICATO: FINITURA: INTERRUZIONE QUOTE IN MILLIMETRI BORDI NETTI...
  • Page 56 Rev.0 18/05/2020 Manuale uso e manutenzione Flexi 7- Flexi 9 Pag.56 Loosen the 4 screws and remove the hatches Clean the hatches GASKET INSPECTION HATCH SE NON SPECIFICATO: FINITURA: INTERRUZIONE SE NON SPECIFICAT NON SCALARE DISEGNO QUOTE IN MILLIMETRI BORDI NETTI...
  • Page 57: Storage And Disposal

    Rev.0 18/05/2020 Manuale uso e manutenzione S70- S90- SC90 Pag.57 STORAGE AND DISPOSAL Disposal Demolition and disposal of the stove is under the exclusive liability and responsibility of the owner who must do so in accordance with the laws in force in the country of installation pertaining to safety, respect and protection of the environment. At the end of its service life, the product must not be disposed of as household waste.
  • Page 58 ITA-Informazioni per la gestione di rifiuti di apparecchiature elettriche ed elettroniche contenenti pile e accumulatori Questo simbolo che appare sul prodotto, sulle pile, sugli accumulatori oppure sulla loro confezione o sulla loro documentazione, indica che il prodotto e le pile o gli accumulatori inclusi al termine del ciclo di vita utile non devono essere raccolti, recuperati o smaltiti assieme ai rifiuti domestici.
  • Page 59 ESP-Información para la gestión de residuos de aparatos eléctricos y electrónicos con pilas y acumuladores Este símbolo que aparece en el producto, en las pilas, los acumuladores o en su embalaje o su documentación indica que el producto y las pilas o acumuladores que contiene, al final de su vida útil, no deben recogerse, recuperarse o desecharse junto con los residuos domésticos.
  • Page 60 Tel. +39.030.7402939 Fax. +39.030.7301758 Internet : www.ravelligroup.it E-mail : info@ravelligroup.it Ravelli does not assume any responsibility for any errors in this booklet and considers itself free to make any variations to the features of its products without notice. Rev.0 PNMU00064 14/07/2020...

This manual is also suitable for:

Flexi 9 decoFlexi 9 glassFlexi 9 steel

Table of Contents