  • Page 2: Product Overview

    DHS Data Logging System Product Overview The DHS Data Logging System for Dry Heat Sterilization is an all in one depyrogenation solution that comes equipped with: • HiTemp140-M12, High Temperature Data Logger • 36 inch Glass Braided RTD depyrogenation probe with M12 connector and flat probe tip •...
  • Page 3 Product User Guide Removing the Data Logger from the Thermal Barrier 1. Unscrew the lid of the thermal barrier. 2. Slide out the data logger and lid from the barrier body. 4. Slide the probe of the data logger out 3.
  • Page 4: Product Maintenance

    $40.00 Prices and specifications subject to change. RMA Instructions To send a device back in to MadgeTech, follow the instructions below to create an (Return Merchandise Authorization) on the MadgeTech website: 1. Visit the Services tab select RMA Process. 2. When the web page opens, please sign in. If this is the first time, select Click here to register an account and create one.
  • Page 5: General Specifications

    Product User Guide General Specifications Temperature Sensor 36 inch Glass Braided RTD depyrogenation probe Temperature Resolution 0.0001 , 0.01 °C (0.02 °F) Temperature Accuracy ±1.2 °C (-200 °C to +400 °C) Probe Measurement Range -200 °C to +400 °C Connector Type M12 Female, 4 Pin Reading Rate 4 readings per second up to 1 reading every 24 hours...
  • Page 6 DHS Data Logging System Thermal Barrier Specifications Operating Environment Refer to the Time vs. Temperature Chart IP Rating Not Rated Barrier Materials 316 Stainless Steel, PTFE, Silicone Enclosure Dimensions 1.75 in OD x 9.6 in L (44.45 mm OD x 243.8 mm L) Weight 3.0 lb (1350 g)
  • Page 7 Product User Guide Time vs. Temperature Chart Ambient Maximum Exposure Temperature Time (air) -200 °C 128 minutes -180 °C 137 minutes -160 °C 148 minutes -140 °C 163 minutes -120 °C 183 minutes -100 °C 213 minutes -80 °C 263 minutes -60 °C 368 minutes -40 °C to +140 °C...
  • Page 8: Disclaimer & Terms Of Use

    MadgeTech with a detailed description of your process, including temperatures, durations, ramp times and process media such as air, steam, oil or water. If MadgeTech is unable to definitively calculate the suitability of our product for your application, a test unit outfitted with a high temperature indicator can be provided.