Power frequency
IEC 61000-4-8
Voltage dips, short
interruptions andvoltage
variations onpower supply
inputlines IEC61000-4-11
Note: Ut is the A.C. mains voltage prior to application of the test level.
Manufacturer's Declaration - Electromagnetic Immunit
or the user of AMM215WTTP should ensure that it is used in such an environment.
Immunity Test
IEC 60601 Test Level
3 V
0.15 MHz - 80 MHz
6V in ISM and amature
Conducted RF
radio bands between
IEC61000-4-6
0.15
MHz and 80 Mhz
Radiated RF
80 % AM at 1 kHz
IEC 61000-4-3
80 MHz - 2.7 GHz
80% AM at 1 kHz
NOTE 1: At 80MHz and 800MHz, the higher frequency range applies.
NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast, connot be predicted theoretically
operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or
relocating the AMM215WTTP.
50 Hz or 60 Hz
0 % U
; 0.5 cycle
T
At 0° . 45°, 90°, 135°, 180°, 225°, 270°, and 315°
0% U
; 1 cycle
T
and
70 % U
T
Single phase: at 0°
0 % U
T
Compliance Level
3 V
0.15 MHz - 80 MHz
6V in ISM and
amature
radio bands between
0.15 MHz and 80 Mhz
80 % AM at 1 kHz
80 MHz - 2.7 GHz
80% AM at 1 kHz
50 Hz or 60 Hz
q
Electromagnetic Environment - Guidance
Portable and mobile RF communications
equipment should be used no closer toany
part of the AMM215WTTP, includingcables,
than the recommended separationdistance
calculated from the equationapplicable to the
frequency of thetransmitter.
Recommended Separation Distance0.15 MHz
to 80 MHz
80 MHz to 800 MHz
800 Mhz to 2.5GHz
where P
rating of the transmitter in watts (W)
according to the transmitter manufacturer
and is the recommended separation
distance in meters (m). Field strengths from
electromagneticsite survey (a), should be less
than the compliance level in each frequency
range(b).Interferency may occur in the vicinity
of equipment marked with the following
symbol:
8
Power frequency magnetic
characteristic of a typical
location in a typical
commercial orhospital
environment.
Mains power quailityshould
be that of a typicalcommercial
or hospitalenvironment. If the
)
user of the AMM215WTTP
requirescontinued operation
during power mains
interruptions, it is commended
that the AMM215WTTP image
uninterruptible power supply
or a battery.