Problem Solving Guide - Miele EVS 7010 Operating And Installation Instructions

Built-in vacuum drawer
Table of Contents

Advertisement

Problem solving guide

Many malfunctions and faults that can occur in daily operation can be easily
remedied. Time and money will be saved because a service call will not be
needed.
The following guide may help you to find the reason for a malfunction or a fault,
and to correct it.
Problem
The drawer will not
open.
The drawer cannot be
switched on.
There was a loud bang
during operation.
The drawer has
switched itself off.
The sensor controls are
not reacting to touch.
32
Cause and remedy
The safety screws on the back of the drawer have not
been removed.
 Call the Miele Service Department.
The appliance is not correctly plugged in and
switched on at the power socket.
 Insert the plug and switch on at the socket.
The fuse has tripped.
 Reset the trip switch in the fuse box or replace the
fuse in the plug (see data plate for minimum fuse
rating). If, after resetting/replacing the trip switch in
the fuse box or the residual current protection
device, the drawer will still not turn on, contact a
qualified electrician or the Miele Customer Service
Department.
The transit device has not been not removed and the
air filter has not been fitted.
 Call the Miele Service Department.
The drawer will switch itself off automatically to save
energy if no other action is taken within a certain time
frame after switching it on or after the end of a vacu-
uming process.
 Switch the drawer back on.
Foreign objects, soiling or liquid residues have got
onto the control panel.
 Remove the objects and/or clean and dry the con-
trol panel.