Download Print this page

First EMV100 800 Series Manual page 55

Product range 2008/1

Advertisement

Technical data
Supply voltage: ............................... 230V, 50Hz +/-10%
Power consumption ........................ 4 VA
Type of thermostat .......................... P
Measurement area ......................... -40°C do 160°C
Adjustable temperature range ........ 10°C - 90°C
Adjustable difference settings ......... 2K - 15K
Hysteresis of difference .................. 1K - 2K
Number of sensors ......................... 2
Output: ........................................... 2x relay: 230V
Inputi: ............................................. 2x sensors
Humidity: ......................................... 5% - 70% (non condensed)
Storehouse temperature: ............... 0°C-70°C
Trouble-shooting guide
TROUBLE
Thermostat inoperative
Water cools down during night
When pump is active,
unplesant noise in installation
is heard
Irrespective of the
temperatures, pump is
inoperative
Irrespective of the temp.,
pump is continuosly switched
on.
When "T1" key(7) is pressed
Er1 appears
When "T1" (7)key is pressed
Er2 appears
Er1 is shown on display
Er2 is shown on display
Control light of the pump is on,
but the pump is inoperative
- pump control
- burner control
- BSF1- PVC (gray) cable, lenght 1,5m (DHWT sensor)
- KF - Silicon (red) cable, lenght 2m (collector sensor)
POSSIBLE FAILURE
Plug not connected
-Selector switch not in AUTO
position
-One of retaining valves
of the system inoperative
(enables thermosiohon water
circulation)
Retaining valve makes noise
(weak spring)
- Selector switch (2) in position
»OFF« - "T2max."(1) set too
low(under 20°C)
Selector switch (2) in "ON"
position
T1 sensor is interrupted
T1 sensor is short circuited
T2 sensor is interrupted
T2 sensor is short circuited
Pump bloked or cable of the
pump interrupted
, 50Hz, 1(1)A, SPST
REMEDY
Connect plug in socket
-Set the switch to AUTO
position
-Check machine installation
We recommend installation of
motor actuated ball valve
Replace nonreturn valve with
motor actuated ball valve
- Set selector switch (2) to
AUTO position
- Increase T2max
Set the switch to AUTO
position
Check T1 senzor
Check T1 senzor
Check T2 senzor
Check T2 senzor
Chek the pump and connection
to regulator
DTC 100/2 TDG
:
55
page

Hide quick links:

Advertisement

loading

Related Products for First EMV100 800 Series