9. Check the wheel lugs. Tighten or replace any lugs that are loose or missing. If a
tire has been replaced or removed for axle service, tighten the lugs, in the order
shown, to the following specifications:
A. Start all lug nuts by hand.
B. First pass tighten to 20-25 ft-lbs (27-33 Nm).
C. Second pass tighten to 50-60 ft-lbs (67-81 Nm).
D. Third pass tighten to 90-120 ft-lbs (122-162 Nm).
Note: After the first road use, re-torque the lug nuts in sequence.
10. Maximum recommended speed for highway towing is 45 mph (72 km/h). Recommended off-road towing speed
is not to exceed 10 mph (16 km/h) or less, depending on the terrain.

LIFTING THE UNIT

WATER TANK MUST BE EMPTY BEFORE LIFTING THE UNIT. Only lift a combination
unit using the lower forklift pockets, do not use the center lift point or mast mounted
forklift pockets. Failure to comply may result in damage to equipment and/or serious
1. Make sure the equipment being used to lift the unit has
sufficient capacity. For approximate weights, refer to
"Specifications" on page
2. Make sure the cradle locking pin is in place.
3. Always remain aware of people and objects around
the unit while moving.
4. Use the lower forklift pockets with care. Approach the
unit as perpendicular as possible to avoid any damage
to the unit. Make sure the mast winch handles or any
other obstructions are clear of the forklift tines before
lifting.

GENERAL MAINTENANCE

Poorly maintained equipment can become a safety hazard. In order for the equipment to operate safely and properly
over a long period of time, periodic maintenance and occasional repairs are necessary. NEVER perform routine
service (oil/filter changes, cleaning, etc.) unless all electrical components are shut off. Before servicing the unit,
always follow the instructions listed below.
Ensure the Control Power switch is turned to the OFF (O) position.
Ensure the circuit breakers are open, in the OFF (O) position.
Activate (push in) the emergency stop switch.
Disconnect the negative (-) terminal on the battery.
Attach a "Do Not Start" sign to the control panel. This will notify everyone that the unit is being serviced and
will reduce the chance of someone inadvertently trying to start the unit.
Never wash the unit with a high pressure hose or with any kind of power washer.
Never wash the engine block or fuel tank with a power washer or steam cleaner. Water may enter the cabinet
and collect in the generator windings or other electrical parts, causing damage.
If the unit is stored outside, check for water inside the cabinet and generator before each use. If wet, dry the
unit thoroughly before starting.
Inspect condition of electrical cords. DO NOT use the unit if insulation is cut or worn through.