2 Mounting

2.4 Other mounting variations

The LST100 transmitter can also be mounted directly
on a tank using either a nut or a sleeve.

2.4.1 Direct installation using a nut

Referring to Fig. 2.8
1. Drill a 38 mm (1.5 in.) hole (for U5 process connection)
or 50.8 mm (2 in.) hole (for U2 process connection) into
the tank.
2. Fit a seal to the LST100 transmitter, insert the transmitter
through the hole and secure from inside the tank using
the nut.
Fig. 2.8: Direct installation using a nut
8 OI/LST100-EN | LST100 – Ultrasonic level transmitter

2.4.2 Direct installation using a sleeve

Referring to Fig. 2.9
1. Select a sleeve that is compatible with NPT or BSP
thread. The LST100 transmitter's thread size is 1.5 in.
(for 20 ft. version) or 2 in. (for the 30 ft. version).
2. Fit a seal to the LST100 transmitter and screw the
transmitter into the sleeve by hand. Note: Tighten
the transmitter hand-tight only – do not use tools.
Fig. 2.9: Direct installation using a sleeve