CIRCUIT BREAKER and SEATING

SEATING

seat swivel lever
(one on each armrest)
©Bruno Independent Living Aids, Inc.
UP/DOWN
rocker switch
6
®
The SRE-2010 includes a circuit breaker
with a built-in ON/OFF switch located on
the back side of the carriage.
The circuit breaker protects the battery,
controller and motor circuits in the stairlift
carriage.
It is unlikely that this circuit breaker will trip
during normal use. However, if the stairlift
becomes inoperative, check the circuit
breaker as a first troubleshooting step. Reset
it, if necessary.
Possible causes of circuit breaker tripping:
• foreign object jamming the rail or gear
rack;
• exceeding the rated weight capacity of
the stairlift.
The seat assembly on the SRE-2010 is
designed to swivel 90 degrees (with standard
armrests), and to lock in one of the following
positions:
0, 60, and 90 degrees at the top,
and (optional) 45 degrees at the
bottom*.
Pull up on either the right- or left-side
swivel lever located under the seat to
swivel the seat to a convenient position for
transferring into or out of the seat.
Once you release the swivel lever, the seat
will lock in the closest of the three positions
indicated above.
To lower the seat assembly from a folded-up
position, simply push down on the seat
cushion to lower it to the riding position.
* If you have the power swivel option, the
seat will swivel from 0-90 degrees only
at the top of the stairway.