CIRCUIT BREAKER

The on/off switch is built into the circuit breaker which is provided to protect the
battery,controller and motor circuits in the Elevator carriage. It is unlikely that this circuit
breaker will ever trip in normal use, but if the Elevator should fail to operate, check the circuit
breaker and reset it if necessary. If the circuit breaker should trip, determine the cause and
correct the situation.
The most likely cause of a tripped circuit breaker would be a foreign object jamming the rail or
gear rack or overloading the elevator by exceeding its rated load capacity.
A fuse has been provided to protect the battery charging circuit and the Call / Send electronics.
The Elevator is shipped with this fuse installed.
CIRCUIT BREAKER WITH ON/OFF
SWITCH BUILT IN
REPLACING A "BLOWN" FUSE:
[ ]
Turn "OFF" the unit using the "ON" / "OFF" switch on the back of the unit.
[ ]
Disconnect the battery charger from the rail charge lead.
[ ]
Remove carriage cover.
[ ]
Determine and repair any short circuit which may have caused the fuse to blow.