Configurable Relay Connection (Alarm) - ABB UNO-2.0-TL-OUTD Product Manual

Solar inverters from 2.0 to 4.2 kw
Hide thumbs Also See for UNO-2.0-TL-OUTD:
Table of Contents

Advertisement

C
onfigurable Relay connection (ALARM)
UNO-2.0/3.0
13
UNO-3.6/4.2
13
Inverter
Settings
Password
0000
Alarms
>Set alarm type
Alarm config
GoGo config
Set alarm type
Production/
Alarm/
Alarm Conf./
Crepuscolar/
Alarm Latch/
Al. Conf. Latch/
Al. Conf. Ext./
GoGo rel(Auto)/
GoGo rel(Slave)/
The configurable relay contacts (ALARM) are not isolated from the accessible communica-
tion ports. Only connect sources which guarantee a voltage not exceeding 24Vdc/12Vac of
safety SELV (Safety Extra Low Voltage).
The inverter is equipped with a relay with configurable activation. It can
be connected with normally open contact (being connected between the
NO terminal and the common contact C) and with normally closed con-
tact (being connected between the NC terminal and the common contact
C).
Different types of devices (light, sound, etc.) can be connected to the
relay, provided they comply with the following requirements:
Relay Rating:
Maximum Voltage: 24 Vdc / 12Vac
Maximum Current: 1 A
SELV
This contact can be used in different operating configurations that can be
selected by accessing the dedicated menu.
- 67 -