13. Disconnect the FP and FN leads.
14. Remove the four bolts to remove the exciter field.
See Figure 9-5.
1
2
1. Bolts (4)
2. Exciter field
Figure 9-5 Exciter Field Removal
15. Remove the three bolts and spacers from the
rectifier board.
16. Disconnect the main field rotor leads from the
rectifier
board
Remove the armature retaining bolt and washer.
See Figure 9-6.
17. Remove the armature from the shaft, guiding the
rotor leads through the armature bores.
Figure 9-6.
1
1. Armature
2. Armature retaining bolt
3. Rotor leads
4. Rectifier board
Figure 9-6 Armature Removal
TP-6255 7/06
positive/negative
terminals.
2
3
4
18. Attach a hoist hook to the generator lifting eye. See
Figure 9-7.
Note: The hoist capacity rating should be one-half
ton or greater.
19. Remove the two vibromount bolts. See Figure 9-7.
20. Raise the alternator end and place a wood block
under the locator plate. Lower the alternator until
the wood block supports the backplate.
Figure 9-7.
21. Remove the four overbolts from the end bracket.
558864
4
1. Lifting eye
2. Backplate
3. Wood block
4. Vibromounts
See
Figure 9-7 Supporting the Generator, Typical
558865
Section 9 Generator Disassembly/Reassembly
1
2
3
See
558866