Component
Generator set master
switch
switch
P1 wiring harness
Controller fuse and
wiring
Auxiliary winding fuse
10 amp fuse
Low oil pressure (LOP)
switch *
Temperature sensor
(CTS) *
Aux. run relay (K5)
* See Section 8.11.2, Fault Shutdown Switches
Figure 8-30 Continuity Checks
TP-6255 7/06
Ohmmeter
Connections
RUN and VBAT
(See Figure 8 29)
(See Figure 8-29)
AUTO and VBAT
(S
(See Figure 8-29)
g
8 9)
P1-27 and ground
P15-1 and P15-3
(stator leads 11 and 44 for
1-phase models)
or
P15-1, P15-2, and P15-3
(stator leads 7, 8, and 9 for
3-phase models)
P16-3 and P16-6 (stator
leads 55 and 66)
P1-24 and battery positive
(+)
P16-3 and stator lead 55
Lead 13 and ground
(engine block)
P1-8 and P1-9
Terminals 85 and 86
Generator Set
Master Switch
Ohmmeter
Position
Scale
R x 100
RUN
OFF/RESET
R x 100
AUTO
OFF/RESET
R x 1
OFF/RESET
R x 1
OFF/RESET
R x 1
OFF/RESET
R x 100
OFF/RESET
R x 100
OFF/RESET
R x 100
OFF/RESET
R x 1000
OFF/RESET
R x 1
OFF/RESET
Section 8 Component Testing and Adjustment
Ohmmeter Readings for Operative
Components*
Zero ohms (continuity). Any other reading
indicates a bad switch.
No reading (open circuit). Any other
reading indicates a bad switch.
Zero ohms (continuity). Any other reading
indicates a bad switch.
No reading (open circuit). Any other
reading indicates a bad switch.
Zero ohms (continuity)
Any other reading indicates a poor ground
connection.
Zero ohms (continuity). If no continuity,
check wiring.
Zero ohms (continuity). If no continuity,
check fuse F1 and wiring.
Zero ohms (continuity). If no continuity is
found, check fuse F3 and wiring.
Zero ohms (continuity). If no continuity is
found, check for an open circuit and/or a
blown fuse.
Zero ohms (continuity). No continuity
indicates a bad switch and/or wiring.
180--2500 ohms, depending on engine
temperature. Zero ohms or an open circuit
indicates bad wiring or a bad switch.
12-volt relay: 85±5 ohms coil resistance
24-volt relay: 305±15 ohms coil resistance
Lower resistance indicates a shorted relay
coil and/or wiring. High resistance indicates
an open relay coil and/or wiring.