Download Print this page

Panduit CT-400 Manual page 4

Advertisement

© Panduit Corp. 2018
6.
If both the GO and NO-GO conditions are met; the tool is dimensionally correct – if either condition fails,
adjust the DIE CLOSURE as follows:
1.
Remove lock screw with small wrench [see FIG. 2].
2.
With adjustment wrench provided, turn adjustment pin one notch – each notch produces approximately
.002" of adjustment. A clockwise turn increases the die closure and a counter-clockwise turn decreases
the die closure.
3.
Close the tool and plug gage the die closure as instructed above. If the GO/NO-GO conditions are not
met, repeat Step (2) in one-notch increments until the tool is gages to be dimensionally correct.
Replace and tighten both lock screws after final adjustment.
7.
If the above procedure fails to satisfy all GO and NO-GO conditions, contact your local Panduit Sales Office;
or contact Technical Support at 1-800-777-3300.
FIG. 6
POCKET
SIZE
22-18 RED
16-14 BLUE
POCKET
SIZE
22-18 RED
16-14 BLUE
CT-400: PA24435A01_04
OPERATION INSTRUCTIONS
CRIMP DIE CLOSURE
GAGING
GO
NO-GO
0.096
0.106
0.114
0.124
INSULATION DIE CLOSURE
GAGING
GO
NO-GO
0.100
0.116
0.142
0.158
GO
0.0960 - 0.0963
0.1140 - 0.1143
GO
0.1000 - 0.1003
0.1420- 0.1423
Page: 4 of 4
CT-400
GAGE ELEMENT
DIAMETERS
NO-GO
0.1057 - 0.1060
0.1237 - 0.1240
GAGE ELEMENT
DIAMETERS
NO-GO
0.1157 - 0.1160
0.1577 - 0.1580
6-2018

Advertisement

loading