INSULATED TERMINAL INSTRUCTIONS
1. With handles in open position, insert terminal in
proper size die so that tongue slides into locator
slot. See product packaging for proper crimping
pockets.
2. Position terminal against locator and close handles
until barrel is held snugly in place -- do not deform
barrel.
3. Insert stripped wire into terminal until conductor
extends beyond barrel. See product packaging for
wire strip length.
4. Crimp by closing handles until controlled cycle
device releases. Handles will open automatically,
and crimped terminal may be removed.
INSULATED SPLICE INSTRUCTIONS
1. Remove locator using a 2mm Allen wrench on the
locator retention screws [see FIG. 1]. (The 2.5mm
wrench may be used simultaneously to secure
screws on opposite side.)
2. With locator removed and handles opened, insert
splice in proper size die so that barrel extends 1/16"
beyond insulation closures.
3. Close handles until barrel is held snugly in position -
- do not deform barrel.
4. Insert stripped wire into splice and crimp by closing
handles until controlled cycle device releases.
5. Remove splice and repeat operation for crimping
other half of barrel.
INSULATED WIRE JOINT INSTRUCTIONS
1. Remove locator using a 2mm Allen wrench on the
locator retention screws [see FIG. 1]. (The 2.5mm
wrench may be used simultaneously to secure
screws on opposite side.)
2. With terminal locator removed, insert wire joint in
proper size die so that ribs of molded insulator are
positioned against face of tool.
3. Twist ends of stripped wire together, trim and insert
into wire joint.
4. Crimp by closing handles until controlled cycle
device releases. Handles will open automatically,
and crimped joint may be removed.
CT-400: PA24435A01_04
OPERATION INSTRUCTIONS
Page: 2 of 4