Categorization By Frame Size And Option Code; Use Of Component Designations; Terms And Abbreviations - ABB ACS880-204LC Hardware Manual

Igbt supply modules
Table of Contents

Advertisement

14 Introduction to the manual
The manual is written for readers worldwide. Both SI and imperial units are shown.

Categorization by frame size and option code

The instructions and technical data which concern only certain module or frame sizes are
marked with a size identifier.
The module size can be identified from the basic code visible on the type designation label,
for example, "ACS880-204LC-0400A-7", where 0400A is the module size. The option codes
of the module are listed after a plus sign. Chapter Ordering information, section Frame R8i
and multiples explains the type designation code in detail.
The frame size of the module can be, for example, R8i or 2×R8i, the latter representing a
supply unit consisting of two parallel-connected R8i supply modules. The table under section
Ratings lists the units and frame sizes.

Use of component designations

Some device names in the manual include the item designation in brackets, for example
[Q20], to make it possible to identify the components in the circuit diagrams of the drive.

Terms and abbreviations

Term
ACS-AP-x
BAMU
BCON
BCU
BDPS
CIO
Control board
Control unit
Cubicle
DC link
DDCS
DI
Drive
EMC
EMI
Frame, frame size
ICU
IGBT
IGBT supply module
IGBT supply unit
Incoming unit
Intermediate circuit
INU
Inverter module
ISU
LCL filter
Description
Assistant control panel
Auxiliary measurement unit
Type of control board
Type of control unit
Internal power supply board in frame R8i modules
I/O module for controlling cabinet fans
Circuit board in which the control program runs
Control board built in a housing (often rail-mountable)
One section of a cabinet-installed drive. A cubicle is typically behind a door of its own.
DC circuit between rectifier and inverter
Distributed drives communication system protocol
Digital input
Frequency converter for controlling AC motors
Electromagnetic compatibility
Electromagnetic interference
Physical size of the drive or power module
Incoming unit
Insulated gate bipolar transistor
IGBT bridge and related components enclosed inside a metal frame or enclosure.
Intended for cabinet installation.
IGBT supply module(s) under control of one control board, and related components.
Part of the cabinet line-up that contains the input power cable terminals. Can also
contain switching equipment etc.
DC circuit between rectifier and inverter
Inverter unit
Inverter bridge, related components and drive DC link capacitors enclosed in a metal
frame or enclosure. Intended for cabinet installation.
IGBT supply unit
Inductor-capacitor-inductor filter

Advertisement

Table of Contents