LED Indicators

The front panel of IE-SW-PL18M Series contains several LED indicators.
The function of each LED is described in the following table:
LED
Color
State
On
PWR1
AMBER
Off
On
PWR2
AMBER
Off
On
FAULT
RED
Off
On
MSTR/HEAD GREEN
Blinking
Off
On
CPLR/TAIL GREEN
Blinking When the Turbo Chain is down.
Off
On
10M
GREEN
Blinking Data is being transmitted at 10 Mbps.
(TP)
Off
100M
GREEN
On
Description
Power is being supplied to power input
P1.
Power is not being supplied to power
input P1.
Power is being supplied to power input
P2.
Power is not being supplied to power
input P2.
When the corresponding PORT alarm is
enabled, and a user-configured event is
triggered.
When the corresponding PORT alarm is
enabled and a user-configured event is
not triggered, or when the
corresponding PORT alarm is disabled.
When the switch is set as the Master of
the Turbo Ring, or as the Head of the
Turbo Chain.
The switch has become the Ring Master
of the Turbo Ring, or the Head of the
Turbo Chain, after the Turbo Ring or
the Turbo Chain is down.
When the switch is not the Master of
this Turbo Ring or is set as the Member
of the Turbo Chain.
When the switch coupling function is
enabled to form a back-up path, or
when it's set as the Tail of the Turbo
Chain.
When the switch disables the coupling
function.
TP port's 10 Mbps link is active.
TP port's 10 Mbps link is inactive.
TP port's 100 Mbps link is active.
- 12 -