Clearing Dc Error Detection Information; Fm/Am Channel Space Switching; Security; Forced Power On Mode - Kenwood DPX-MP3110 Service Manual

Hide thumbs Also See for DPX-MP3110:
Table of Contents

Advertisement

DPX-MP3110/MP3110S
DPX-MP5110U/MP5110US
■ Clearing DC error detection information (E2PROM data clearing)
While pressing and holding [3] key and [6] key, reset-start.
While "– – – –" is displayed, power can be ON for 30 minutes. This mode is cancelled by resetting. (The last screen will not be retained.)
Procedure
While pressing
D
C
and holding [3]
key and [6] key,
D
C
reset-start.
D
C
1
D
C
■1
D
C
2
D
C
■2
D
C
This mode is cancelled by resetting. (The last screen will not be retained.)

■ FM/AM channel space switching

While Power OFF, pressing and holding [1] key and [5] key,
and press [SRC] key to Power ON

■ Security

• Forced Power ON mode

While pressing and holding [M.JOG] key and [4] key, reset-start.
• How to register the security code on the "Car Audio Passport" after replacement of the FRONT-END
with E2PROM
While pressing and holding [1] key and [3] key, reset-start
Press [M.JOG] key briefl y
Press and hold [AUD] key for 1 second or longer
[FM] / [AM] / [
] / [
] key
Press and hold [AUD] key for 3 second or longer
[FM] / [AM] / [
] / [
] key
Press and hold [AUD] key for 3 second or longer
Reset, Momentary power down, ACC OFF, Power OFF, panel removed
Note: The security code in this model cannot be all-cleared.
18
Procedure
Display
When DC error is detected (when either one of capacitor leak is leaking, or an im-
E
R
R
proper connection or other error is detected)
When DC error is not detected (when none of capacitor leak, no improper connection
O
K
or other error is detected)
When improper connection or other DC errors are detected.
1
E
R
R
When improper connection or other DC errors are detected.
1
O
K
When detecting improper connection or other DC errors, clears detection data. (Clear
1
O
K
EEPROM)
Capacitor leak detection period display of the detected times of capacitor leaks. (0~4)
2
4
Capacitor leak detection period to clear the times of the detections. (Clear EEPROM)
2
0
Procedure
Procedure
Procedure
TEST MODE
To enter DC error display mode.
FM200kHz/AM10kHz ↔ FM50kHz/AM9kHz
FM50kHz/AM10kHz ↔ FM200kHz/AM10kHz
While "– – – –" is displayed, power can be turned ON for only 30
minutes. After 30 minutes, can only be recovered by resetting.
Enters the Test mode
Enter the Menu mode.
Enter the Security Registration mode.
Input the code. FM: Number up / AM: Number down /
: Cursor to the left /
"RE-ENTER" is displayed.
Inputs the code again. FM: Number up / AM: Number down /
: Cursor to the left /
"APPROVED" is displayed.
Cancel the Test mode.
Note
Description
Note
Note
Description
: Cursor to the right
: Cursor to the right