Cd Information Display Mode - Kenwood DPX-MP3110 Service Manual

Hide thumbs Also See for DPX-MP3110:
Table of Contents

Advertisement

Key
Description of display
ROM data transfer
■AM
Audio data initialization
Forced Power OFF
information display
Disc Information display
mode ON/OFF

• CD information display mode

Key
CD mecha-
/
nism error
log display
CD load er-
/
ror informa-
tion display
CD ejec-
FM
/
tion error
(forward
information
rotation)
display
AM
(reverse
rotation)
CD time
code er-
ror count
/
information
display
(Missing
counts)
CD time
code error
count infor-
/
mation dis-
play (Count
is not
updated.)
TEST MODE
A
U
D
I
N
I
P
O
F
F
P
O
F
F
S
E
P
O
F
F
P
N
Description of display
M
C
E
R
R
1 : X
X
M
C
E
R
R
2 : X
X
M
C
E
R
R
3 : X
X
L
D
E
R
R
1 : X
X
L
D
E
R
R
2 : X
X
E
J
E
R
R
1 : X
X
E
J
E
R
R
2 : X
X
E
J
E
R
R
3 : X
X
E
J
E
R
R
4 : X
X
C
N
T
L
O
S
E
C
D
D
A
: X
X
C
D
R
O
M
: X
X
C
N
T
S
T
A
Y
C
D
D
A
: X
X
C
D
R
O
M
: X
X
Audio setting value is re-set to the Test mode default value.
T
No forced Power OFF
Power is turned OFF forcibly because the Security Code is not yet
C
written.
Forced power OFF by communication error between system μ-com
L
and panel.
While the forced power OFF data is displayed, press and hold for 2
seconds to clear the data.
Refer to CD information display mode for what are displayed.
While in information display mode, press and hold for 2 seconds to
clear selected source.
Mechanism error log 1 (Latest)
XX: Error number. The "– –" is displayed in case there is no error.
Mechanism error log 2 (Latest)
XX: Error number. The "– –" is displayed in case there is no error.
Mechanism error log 3 (Latest)
XX: Error number. The "– –" is displayed in case there is no error.
Load error switch 1
XX: The number of errors. The "– –" is displayed in case there is no error.
Load error switch 2
XX: The number of errors. The "– –" is displayed in case there is no error.
Ejection error switch 1
XX: The number of errors. The "– –" is displayed in case there is no error.
Ejection error switch 2
XX: The number of errors. The "– –" is displayed in case there is no error.
Ejection error switch 3
XX: The number of errors. The "– –" is displayed in case there is no error.
Ejection error switch 4
XX: The number of errors. The "– –" is displayed in case there is no error.
CD time code error count information (Missing counts) mode is display.
Number of CD-DA error counts
XX: The number of errors (Max. 99).
The "– –" is displayed in case there is no error.
CD-ROM (Compression fi le) number of count errors
XX: The number of errors. The "– –" is displayed in case there is no error.
CD time code error count information (Count is not updated) mode display.
Number of CD-DA error counts
XX: The number of errors (Max. 99).
The "– –" is displayed in case there is no error.
CD-ROM (Compression fi le) number of count errors
XX: The number of errors. The "– –" is displayed in case there is no error.
DPX-MP3110/MP3110S
DPX-MP5110U/MP5110US
Description
Description
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dpx-mp3110sDpx-mp5110uDpx-mp5110us