Page 1
16575177 Edition 1 June 2006 Electric Angle Wrench QE8 Series Maintenance Information Save These Instructions...
Page 2
Ingersoll Rand #67 Grease as follows: • Use of non-Ingersoll Rand parts or failure to follow • 2 to 3 cc to central area between gears of 1st Stage Maintenance Instructions may create a risk of electric Spindle Assembly (36) shock or injury.
Page 3
7. Using an adjustable Pin Wrench, unscrew Bearing 5. Remove Retaining Ring (14) from behind Label Cover Cap (73). Lens (13). 8. Pull the Drive Spindle Assembly (69) out of Housing 6. In a sliding motion, pull Warning Label (12) and Label Assembly (61).
Disassembly of Internal Components 7. Remove LED Board from Motor Housing Assembly. (Refer to TP2162b) 1. Remove Retainer (9) used to retain Communication Transducer Removal Board (8), located at rear end of Motor Housing Assembly in Connector cavity. 1. Locate the cavity found at end of long axial groove 2.
Transducer Installation CAUTION 1. Insert Transducer Assembly (31) into the Motor Housing Assembly, wire end first, guiding Transducer's connector • When replacing an Attachment, always use the Angle out through the cavity found at end of Motor Housing Head Attachment designed for that model. Never Assembly's long outer groove.
Page 6
5. Socket Retaining Pin is properly installed when Socket Retaining Spring snaps into place. 6. Lubricate the bearings of the Housing Assembly (61) with Ingersoll Rand # 67 Grease. 7. Slide Washer (62) and Washer (63) onto Square Drive Spindle and insert Square Drive Spindle (64) into Housing Assembly (61).
Page 7
The use of other than genuine Ingersoll Rand replacement parts may result in safety hazards, decreased motor performance, and increased maintenance, and may invalidate all warranties. Ingersoll Rand is not responsible for customer modification of motors for applications on which Ingersoll Rand was not consulted.