E - Preventive Maintenance; Changing The Fuse; What To Do If - Technifor UC500 Operating And Maintenance Manual

For marking machines
Table of Contents

Advertisement

1. Changing the fuse

Turn off the CCU before any intervention.
Unplug the power supply cord.
Extract the fuse holder with 2 screwdrivers.
Insert the new fuse.
Pneumatic machines
Fuse 5x20 - 3.15 A UL 198-G - CSA C22-2 norm Time-delay
Electromagnetic machines
Fuse 5 x 20 - 6 A UL 198-G and CSA C22-2 norm Time-delay

2. What to do if...

Description
The screen on the front panel of
the CCU does not light up.
Lost in the program?
Ref. DCD01/3067 - UC500_en_D
Preventive maintenance
E
Turn off the CCU before any intervention.
Things to check
Is the power supply switched on?
Is the cable properly connected?
Is the On/Off switch in the On position?
Check the condition of the fuse.
Refer to the manual.
Power
Power supply
3.15 A
90-253 V AC
Power
Power supply
6 A
90-253 V AC
Action
See: Power supply connection
See: Changing the fuse
Press Esc and answer "no" to the questions
from the program until you're back to the
main menu.
E
Ref.
ELE01/3427
Ref.
SEUC005/16
26/27