Generic Inputs/Outputs; Wiring Of The Female 25 Subd Connector - Technifor UC500 Operating And Maintenance Manual

For marking machines
Table of Contents

Advertisement

3. Generic Inputs/Outputs

Wiring of the female 25 SubD connector

This connector allows the connection of generic Inputs/Outputs.
Use exclusively shielded cable. Connect the shielding to the electrical ground on
either side of the cable.
Pin functions
Number
Description
1
+ 24 V - 300 mA max.
2
Input
3
Input
4
Input
5
Input
6
Negative reference of the
7
Gnd
8
Output O0
9
Output O1
10
Gnd
11
Not connected
12
Not connected
13
Not connected
14
+ 24 V - 300 mA max.
15
Input
16
Input
17
Input
18
Input
19
Negative reference of the
20
Gnd
21
Output O2
22
Output O3
23
Gnd
24
Not connected
25
Not connected
Ref. DCD01/3067 - UC500_en_D
Communication
A
0
I
1
I
2
I
3
I
0 -
1 -
I
I
4
I
5
I
6
I
7
I
4 -
5 -
I
I
2 -
3 Inputs (common)
I
I
6 -
7 Inputs (common)
I
I
13
25
C
1
14
18/27