C - Communication; Rs232 Cable; Dedicated Inputs/Outputs; Wiring Of The Female 9 Subd Connector - Technifor UC500 Operating And Maintenance Manual

For marking machines
Table of Contents

Advertisement

1. RS232 cable

Sub. D9F
1
RD
2
3
TD
4
OV
5
6
RTS
7
CTS
8
9
Grounding
Metallic SubD9F for shielded cables

2. Dedicated Inputs/Outputs

Wiring of the female 9 SubD connector

This connector allows to communicate with the machine. It contains
dedicated All-or-Nothing Inputs and Outputs. They are used in the
marking cycle.
Use exclusively shielded cable. Connect the shielding to the electrical ground on
either side of the cable.
Pin functions
Number
Description
1
Internal power supply
2
Relay # 2
3
Relay # 3
4
Input 1
5
Gnd
6
Relay # 1
7
Common Relay # 1-2
8
Relay # 3
9
Input 2
Ref. DCD01/3067 - UC500_en_D
Communication
C
2 m (6.56 ft)
Sub. D9F
5
9
Allocation
+ 24 V - 300 mA max.
Output - Fault
Output - Marking in progress
Input - Start marking
Grounding
Output - Machine ready
Output - Marking in progress
Input - Stop marking
C
1
2
3
4
5
6
7
8
9
Grounding
1
6
12/27