Basic Safety Instructions Always read through and comply with the following safety instructions! All plants and locations of the Rohde & Schwarz group of companies make every effort to keep the safety standards of our products up to date and to offer our customers the highest possible degree of safety. Our products and the auxiliary equipment they require are designed, built and tested in accordance with the safety standards that apply in each case.
Page 4
Basic Safety Instructions Symbol Meaning Symbol Meaning Caution ! Hot surface Alternating current (AC) Protective conductor terminal Direct/alternating current (DC/AC) To identify any terminal which is intended for connection to an external conductor for protection against electric shock in case of a fault, or the terminal of a protective earth Earth (Ground) Class II Equipment...
Page 5
Basic Safety Instructions Operating states and operating positions The product may be operated only under the operating conditions and in the positions specified by the manufacturer, without the product's ventilation being obstructed. If the manufacturer's specifications are not observed, this can result in electric shock, fire and/or serious personal injury or death. Applicable local or national safety regulations and rules for the prevention of accidents must be observed in all work performed.
Page 6
Basic Safety Instructions 6. The product may be operated only from TN/TT supply networks fuse-protected with max. 16 A (higher fuse only after consulting with the Rohde & Schwarz group of companies). 7. Do not insert the plug into sockets that are dusty or dirty. Insert the plug firmly and all the way into the socket provided for this purpose.
Page 7
Basic Safety Instructions 2. Before you move or transport the product, read and observe the section titled "Transport". 3. As with all industrially manufactured goods, the use of substances that induce an allergic reaction (allergens) such as nickel cannot be generally excluded. If you develop an allergic reaction (such as a skin rash, frequent sneezing, red eyes or respiratory difficulties) when using a Rohde &...
Page 8
Basic Safety Instructions 2. Adjustments, replacement of parts, maintenance and repair may be performed only by electrical experts authorized by Rohde & Schwarz. Only original parts may be used for replacing parts relevant to safety (e.g. power switches, power transformers, fuses). A safety test must always be performed after parts relevant to safety have been replaced (visual inspection, protective conductor test, insulation resistance measurement, leakage current measurement, functional test).
Page 9
Instrucciones de seguridad elementales 3. If you use the product in a vehicle, it is the sole responsibility of the driver to drive the vehicle safely and properly. The manufacturer assumes no responsibility for accidents or collisions. Never use the product in a moving vehicle if doing so could distract the driver of the vehicle.
Page 10
Instructions - Instrucciones Instructions for Electrostatic Discharge Protection Risk of damaging electronic components To avoid damage of electronic components, the operational site must be protected against electrostatic discharge (ESD). Wrist strap with cord Floor mat Heel strap Ground connection of operational site The following two methods of ESD protection may be used together or separately: , Wrist strap with cord to ground connection...
Page 11
Customer Support Technical support – where and when you need it For quick, expert help with any Rohde & Schwarz equipment, contact one of our Customer Support Centers. A team of highly qualified engineers provides telephone support and will work with you to find a solution to your query on any aspect of the operation, programming or applications of Rohde &...
Notes on Safety R&S RT-ZC30 Notes on Safety Thank you for purchasing the R&S RT-ZC30 current probe. To obtain maximum performance from the device, please read this manual first, and keep it handy for future reference. Risk of physical injury This device is designed to comply with IEC 61010 Safety Standards, and has been thoroughly tested for safety before shipment.
Page 15
® Notes on Safety R&S RT-ZC30 Risk of fatal injury ● To avoid electric shock, do not remove the device's cover. The internal components of the device carry high voltages and may become very hot during operation. ● To avoid electric shock and short circuits, never attach the clamp to bare, unisolated conductors.
Page 16
® Notes on Safety R&S RT-ZC30 Risk of fatal injury ● This device is made for use with the R&S RT-ZA13 probe power supply. ● When using a measurement instrument that does not provide isolation between its input terminals and chassis or other input terminals, please pay attention to the following points.
Page 17
® Notes on Safety R&S RT-ZC30 Risk of instrument damage ● To avoid damage to the device, protect it from vibration or shock during transport and handling, and be especially careful to avoid dropping. ● To avoid damage to the device, do not place the device on an unstable table or an inclined place.
Page 18
® Notes on Safety R&S RT-ZC30 ● Keep the sensor head closed when not in use, to avoid accumulating dust or dirt on the mating core surfaces, which could interfere with clamp performance. ● Avoid stepping on or pinching the cable, which could damage the cable insulation.
Product Description Product Overview The R&S RT-ZC30 is an AC/DC current probe. It allows the user to make current measurements from DC to 120 MHz. By clamping on the conductor to be mea- sured, the current waveform is captured easily without interrupting the electric cir- cuit.
® Product Description R&S RT-ZC30 Description of the Probe If the contents are incomplete or damaged, notify your Rohde & Schwarz ser- vice center. The following accessories are delivered with the probe: – User manual – Carrying case – R&S RT-Zxx datasheet –...
® Product Description R&S RT-ZC30 Description of the Probe Power plug Connect the plug to the R&S RT-ZA13 probe power supply receptacle to supply power to the sensor. 2.4.3 Sensor RT-ZC30 Figure 2-3: Sensor overview 1 = Current direction indication...
® Product Description R&S RT-ZC30 Description of the Probe 2.4.4 Key and LEDs Figure 2-4: Key and LEDs 1 = DEMAG/AUTO ZERO LED 2 = DEMAG/AUTO ZERO Key 3 = OVERLOAD 4 = JAW UNLOCKED LED 5 = POWER LED The key is used to perform demagnetization and zero adjustment, while the LEDs indicate the device status.
Page 24
® Product Description R&S RT-ZC30 Description of the Probe Color State ● Slow flashing Before demagnetization and zero adjustment (when either can be per- orange formed) ● After an overload is detected ● When demagnetization terminated abnormally Orange During demagnetization and zero adjustment process...
2. Turn the power switch off and connect the power cord. 3. Connect the power plug of the R&S RT-ZC30 to the power receptacle of the R&S RT-ZA13 probe power supply. User Manual 1409.7872.02 ─ 02...
Page 26
The POWER LED lights up in green and the DEMAG/AUTO ZERO LED is slowly flashing in orange. 6. Connect the output connector of the R&S RT-ZC30 to one of the BNC input connectors of the oscilloscope. Turn the collar until it clicks, and check that it is locked securely.
Page 27
® Measuring Procedure R&S RT-ZC30 Preparing the Measurement Risk of instrument damage ● Check that the conductor being measured is not clamped when supply- ing power to the device. A demagnetizing waveform may be generated when power is supplied, causing damage to components connected to the circuit being measured.
Demagnetizing and Zero Adjustment Risk of circuit damage ● Do not demagnetize while the R&S RT-ZC30 is clamping a conductor to be measured. Demagnetizing causes current to flow into the conductor, which may damage parts in the circuit to be measured.
® Measuring Procedure R&S RT-ZC30 Connecting the Probe to the DUT Risk of instrument damage When opening the sensor head, always operate the opening lever. Subject- ing the sensor head to force from the directions shown in the figure while it is locked may damage the clamping mechanism.
Page 30
® Measuring Procedure R&S RT-ZC30 Connecting the Probe to the DUT If the sensor head is not properly closed, accurate measurement is not possi- ble. ● To measure DC or low-frequency current, multiple windings may be used to increase relative sensitivity (10 windings multiplies the mea- sured current by a factor of 10).
Page 31
® Measuring Procedure R&S RT-ZC30 Connecting the Probe to the DUT Risk of instrument damage due to continuous input current ● The maximum continuous input range is based on heat that is internally generated during measurement. Always keep the input current below this level.
Page 32
® Measuring Procedure R&S RT-ZC30 Connecting the Probe to the DUT Risk of instrument damage due to continuous input current ● At high ambient temperatures, the built-in safety circuit may activate at current input levels below the rated continuous maximum current.
Page 33
® Measuring Procedure R&S RT-ZC30 Connecting the Probe to the DUT ● Immediately after powering on, this device may be subject to an appre- ciable offset drift due to the effect of self-heating. To counteract this, allow the device to warm up for about 30 minutes before carrying out measurements.
® Measuring Procedure R&S RT-ZC30 Disconnecting the Probe from the DUT At high frequencies, common mode noise may affect measurements taken on the high voltage side of circuits. If this occurs, reduce the frequency range of the waveform measuring instrument, or clamp onto the low-voltage side of the circuit, as appropriate.
® Measuring Procedure R&S RT-ZC30 Troubleshooting Risk of instrument damage ● To prevent wire breaks, do not pull on the cord to disconnect the output connector from the waveform measurement instrument. Always grip the terminator and pull the unlock lever toward you before disconnecting the connector.
Page 36
® Measuring Procedure R&S RT-ZC30 Troubleshooting Error State Meaning This issue occurs when the DEMAG/ AUTO ZERO key is pressed under the circumstances described in the table below. Demagnetization and automatic zero adjustment cannot be performed. Perform demagnetization and zero adjustment again after implementing the rem- edy described below.
Rohde & Schwarz service center. Return a defective probe to the Rohde & Schwarz service center for diagnosis and exchange. You can return the R&S RT-ZC30 current probe for calibration. The service per- sonnel will perform the required tests.
Before using the probe again, make sure to dry it com- pletely. Calibration Interval The recommended calibration interval for R&S RT-ZC30 current probe is two years. For servicing, send the probe to your nearest Rohde & Schwarz service center (see Chapter 4.2, "Returning the Probe for...
® R&S RT-ZA13 Probe Power Supply R&S RT-ZC30 R&S RT-ZA13 Probe Power Supply This unit is a special-purpose power supply for the R&S RT-ZC10 and R&S RT- ZC20 current probes. You can connect up to four current probes to the power supply.