Do you want to start a defrost operation?
Disable protections
The software is equipped with an "installer-on-site" mode ([A.6.D]:
Disable protections) that disables automatic operation by the unit.
#
Code
[A.6.D]
N/A
▪ ON: Automatic operation is disabled.
All protective functions are disabled. If
the user interface home pages are off,
the
automatically. To enable automatic
operation and the protective functions,
set Disable protections=OFF.
▪ OFF: 12 hours after the first power-on,
the unit will automatically set Disable
protections=OFF, ending "installer-on-
site" mode and enabling the protective
functions. If the installer returns to the
site, the installer has to set Disable
protections=ON manually.
Pump operation
When the pump operation function is disabled the pump will stop if
the outdoor temperature is higher than the value set by [4‑02] or if
the outdoor temperature drops below the value set by [F‑01]. When
the pump operation is enabled, the pump operation is possible at all
outdoor temperatures.
#
Code
N/A
[F‑00]
Pump operation:
▪ 0: Disabled if outdoor temperature is
higher than [4‑02] or lower than [F‑01]
depending on heating operation mode.
▪ 1:
temperatures.
Pump speed limitation
Pump speed limitation [9‑0D] defines the maximum pump speed. In
normal conditions, the default setting should NOT be modified. The
pump speed limitation will also be overruled when delta  T is
abnormal.
#
Code
N/A
[9‑0D]
Pump speed limitation
▪ 0: No limitation.
▪ 1~4: General limitation. There is
limitation
required delta  T control and comfort
are NOT guaranteed.
▪ 5~8: Limitation when no actuators.
When there is no heating output, the
pump speed limitation is applicable.
When there is heating output, the
pump speed is only determined by
delta  T in relation to the required
capacity. With this limitation range,
delta  T is possible and the comfort is
guaranteed.
EJHA04AAV3 + EHY2KOMB28+32AA
Daikin Altherma Hybrid hydrosplit heat pump
4P531180-1 – 2018.06
Description
Description
unit
will
NOT
operate
Description
Possible
at
all
outdoor
Description
in
all
conditions.
The
The maximum values depend on the unit type:
[9-0D]=0
a (kPa)
b (l/min)
[9-0D]=6
a (kPa)
b (l/min)
[9-0D]=8
a (kPa)
b (l/min)
a
External static pressure
b
Water flow rate
10 Configuration
[9-0D]=5
a (kPa)
b (l/min)
[9-0D]=7
a (kPa)
b (l/min)
Installer reference guide
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Altherma ehy2komb32aaAltherma ehy2komb28aa

Table of Contents