5 Installation
3
4×
2×
1 Open the top plate.
2 Open the front plate.
3 If necessary, open the rear plate. This is, for example,
necessary in the following cases:
▪ When you install the freeze protection valve inside the
outdoor unit.
▪ When you install the bottom plate heater.
5.2
Mounting the outdoor unit
5.2.1
To provide the installation structure
This topic shows different installation structures. For all, use 4 sets
of M8 or M10 anchor bolts, nuts and washers. In any case, provide
at least 300 mm of free space below the unit. Additionally, make
sure the unit is positioned at least 100 mm above the maximum
expected level of snow.
INFORMATION
The maximum height of the upper protruding part of the
bolts is 15 mm.
Anchor points
(mm)
574
Installation manual
10
2×
1
2
2×
4× M8/M10
Option 1: On mounting feet "flexi-foot with strut"
(mm)
a
Maximum snowfall height
Option 2: On plastic mounting feet
Option 3: On a pedestal
(mm)
Daikin Altherma hybrid monobloc – Heat pump module
EJHA04AAV3
4P530607-1B – 2018.10