5
Dimensional drawing & centre of gravity
5 - 1 Dimensional drawing
FXCQ63MVE
1
5
Suspension bolt
Branch duct connection
(knock hole)
hole (Circumference)
Fresh air intake
FXCQ80-125MVE
1220 (Suspension position)
Suspension bolt
Branch duct connection
(knock hole)
hole (Circumference)
Fresh air intake
12
• Indoor Units • 2-Way Blow Ceiling Mounted Cassette • FXCQ-MVE9
1220 (Suspension position)
1309 (Ceiling opening)
Decoration panel
Brand name plate (Note 3)
A View
1309 (Ceiling opening)
or less
Decoration panel
Brand name plate (Note 3)
A View
®
• VRV
Systems • Indoor Units
Nr
1
2
3
4
5
6
7
8
Branch duct connection
9
BView
1
2
3
- Require space
4
or more
or more
or more
Nr
1
2
3
4
5
6
7
8
Branch duct connection
9
BView
1
2
- Require space
3
4
or more
or more
or more
Name
Liquid pipe connection port:
ø 9.5 flare connection
Gas pipe connection port:
ø 15.9 flare connection
Drain pipe connection port:
VP25 (O.D. ø 32, I.D. ø 25)
Power wiring port
Air discharge port
Air suction grille
Port for water supply
Drain hose
O.D. ø 32
Socket for drain
NOTES
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
When installing an optional accessory, refer to the installation
drawings.
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.
Glass fiber of polyethylene foam.
Name
Liquid pipe connection port:
ø 9.5 flare connection
Gas pipe connection port:
ø 15.9 flare connection
Drain pipe connection port:
VP25 (O.D. ø 32, I.D. ø 25)
Power wiring port
Air discharge port
Air suction grille
Port for water supply
Drain hose
O.D. ø 32
Socket for drain
NOTES
Location of unit's name plates
For main body : Filter install plate inside surface of suction grille
For decoration panel: Panel frame inside surface of suction grille.
When installing an optional accessory, refer to the installation
drawings.
In case of using wireless remote control, this position will be a
signal receiver. Refer to the drawing of infrared remote control in
detail.
If it is assumed that the relative humidity above the ceiling
exceeds 80% stic the additional insulation to the unit.
Insulation: 10 mm thick or more.