Daikin FFQ12LVJU Operation Manual

Vrv/split system inverter air conditioners
Hide thumbs Also See for FFQ12LVJU:

Advertisement

Quick Links

/SPLIT SYSTEM Inverter Air Conditioners
MODELS
(Ceiling mounted Multi flow Cassette type)
FFQ09LVJU
FFQ12LVJU
FFQ15LVJU
FFQ18LVJU
FXZQ07MVJU9
FXZQ09MVJU9
FXZQ12MVJU9
FXZQ15MVJU9
FXZQ18MVJU9
Read these instructions carefully before installation.
Keep this manual in a handy place for future reference.
This manual should be left with the equipment owner.
Lire soigneusement ces instructions avant l'installation.
Conserver ce manuel à portée de main pour référence ultérieure.
Ce manuel doit être donné au propriétaire de l'équipement.
Lea cuidadosamente estas instrucciones antes de instalar.
Guarde este manual en un lugar a mano para leer en caso de tener alguna duda.
Este manual debe permanecer con el propietario del equipo.
3P184442-11P
OPERATION MANUAL
English
Français
Español

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FFQ12LVJU

  • Page 1 OPERATION MANUAL /SPLIT SYSTEM Inverter Air Conditioners MODELS (Ceiling mounted Multi flow Cassette type) English FFQ09LVJU FFQ12LVJU FFQ15LVJU Français FFQ18LVJU FXZQ07MVJU9 Español FXZQ09MVJU9 FXZQ12MVJU9 FXZQ15MVJU9 FXZQ18MVJU9 Read these instructions carefully before installation. Keep this manual in a handy place for future reference.
  • Page 2: Safety Considerations

    Grounding wire Conducts electricity from the unit into the ground to prevent electric shock. Remote controller Thank you for purchasing this Daikin air Meanings of DANGER, WARNING, CAUTION, conditioner. Carefully read this operation manual and NOTE Symbols: before using the air conditioner. It will tell you how DANGER .
  • Page 3 • Placing a flower vase or other containers with water or other liquids on the unit could cause a shock or fire if a spill occurs. WARNING • Do not touch the air outlet or horizontal • Contact your dealer for repair and blades while the swing flap is in operation maintenance. Improper repair and because fingers could get caught and maintenance may result in water injured. leakage, electric shock, and fire. Only • Never touch the internal parts of the use accessories made by Daikin that are controller. Do not remove the front panel specifically designed for use with the because some parts inside are dangerous equipment and have them installed by a to touch. To check and adjust internal parts, professional. contact your dealer. • Contact your dealer to move and reinstall the air conditioner. Incomplete installation may result in water leakage, electric shock, and fire. 3P184442-11P English...
  • Page 4 • Be sure to establish a ground. • Consult with the installation contractor for Do not ground the unit to a utility pipe, cleaning. arrester, or telephone ground. Incomplete • Incorrect cleaning of the inside of the air grounding may cause electrical shock, or conditioner could make the plastics parts fire. A high surge current from lightning or break and cause water leakage or electric other sources may cause damage to the air shock. conditioner . • Do not touch the air inlet or aluminum fin • Be sure to install a ground fault circuit of the air conditioner as they can cut and interrupter. cause injury. Failure to install a ground fault circuit • Do not place objects in direct proximity interrupter may result in electric shocks, or of the outside unit . Do not let leaves and fire.
  • Page 5: Maintenance

    a . Places with a mist of mineral oil, such as MAINTENANCE cutting oil. (FOR SERVICE PERSONNEL) b. Locations such as coastal areas where there is a lot of salt in the air . WARNING c . Locations such as hot springs where • Only a qualified person is allowed to there is a lot of sulfur in the air . perform maintenance without daily d .
  • Page 6: How To Clean The Air Filter

    HOW TO CLEAN THE AIR FILTER NOTE • Do not wash the air filter with hot water of more Clean the air filter when the display shows “ ” than 122°F. Doing so may result in discoloration (TIME TO CLEAN AIR FILTER). and/or deformation.
  • Page 7: How To Clean The Suction Grille

    HOW TO CLEAN THE SUCTION NOTE • Do not wash the air conditioner with hot water GRILLE of more than 122°F. Doing so may result in discoloration or deformation. 1 . Open the suction grille. Push it downward slowly while pressing the 5 . Fix the air filter. buttons provided on two spots.
  • Page 8 3P184442-11P EM12A029 (1211) DE...

Table of Contents