GE Becker 3.5M Series Instruction Manual page 20

Digital natural gas positioner with modbus protocol
Table of Contents

Advertisement

Figure 28 - Linear Transmitter Wiring Diagram
Table 9 - Programmable Linear Position Transmitter Specifi cations (Supplied 2006 and later)
Measured Parameter
Voltage-Output Versions
Repeatability
(Resolution + Hysteresis)
Current-Output Versions
For stroke lengths ≤ 2000 mm
Sampling Rate
For stroke lengths > 2000 mm
For stroke lengths ≤ 500 mm
Non-linearity
For stroke lengths > 500 mm
Pressure Rating (Rod)
Up to 600 bar
-40°F to +185°F
Operating Temperature
Supply Voltage
+24 VDC ± 20%
Humidity
<90% non-condensing
20
Specifi cation
0.5 mV or 5 μm (whichever is greater)
1 μA or 5 μm (whichever is greater)
1 kHz
500 Hz
± 100 μm
± 0.02% of full-scale
Analog Output