1.3 Alarm Input/Output
Network positioning system can be connected with alarm input (0 to 5 VDC) and alarm
output as shown in Figure 1-14. The alarm provides the relay output (no voltage), and
the external power supply is required when it connects to the alarm device.
Positioning System OUT(n)
Relay Output
OUT(n)
Diagram (left)
For DC power supply (left diagram), the input voltage must be no more than 30 VDC,
1A.
For AC power supply, the external relay must be used (right diagram) to prevent
damages to the positioning system and avoid risk of electric shock.
Note:
Alarm input/output function varies depending on different positioning system models.