Cooktop burners
PROBLEM
There is a power failure
– can I still use the
cooktop burners?
The flames have
suddenly gone out.
There is a slight
'extinction pop' or
flash after I've turned a
cooktop burner off.
The burner flames are
uneven, very large, yellow
or yellow-tipped or sooty.
70
TROUBLESHOOTING
POSSIBLE CAUSES
Power outage in your area.
A draft or a spill has extinguished
the flame.
Technical fault: the gas is the
wrong type or hasn't been
adjusted properly.
WHAT TO DO
The cooktop burners can still be
used. To light them:
1 Holding a lighted match to
the flame spreader, push in
on the control dial and turn
anticlockwise to LITE.
2 When the flame is burning all
the way around the burner,
you may adjust the heat.
IMPORTANT!
If the flame is blown out
during a power failure, turn
the dial immediately to O
(OFF), as the burner will not
automatically relight and
gas may escape.
No action required. The burner
will detect this and automatically
relight. However, if there has
been a large spill, we recommend
turning the burners off and
cleaning the burners and sump
area. See 'Care and cleaning'
for instrucions.
This is normal for LP gas and
requires no action.
Do not use your cooktop burners.
Contact your Authorised Service
Center or Customer Care.