Problem
Plugged drain line flow control.
Plugged injector and/or filter.
Low water pressure.
Softener fails to
draw brine
Internal valve leak.
Bad programming.
Power head not operating properly.
Power head not operating properly.
Controller cycles
Faulty microswitch or wiring loom.
continuously
Defective or badly set cycle cam.
Foreign elements in the valve.
Internal valve leak.
Drain flows
Valve blocked in brine refill or
continuously
backwash.
Defective or blocked motor.
Power head not operating properly.
Ref. MKT-IM-027 / B - 01.06.2018
Installer Manual Fleck 4600 - MECH - Troubleshooting
Cause
Solution
Clean drain line flow control.
Clean or replace injector and/or filter.
Raise inlet pressure to 1.8 bar
minimum.
Change seals & spacers and/or piston
assembly.
Program correctly.
Change power head.
Change power head.
Change microswitch or wiring loom.
Reposition or change cycle cam.
Clean valve and check it in the different
regeneration positions.
Change seals & spacers and/or piston
assembly.
Change motor and check gear teeth.
Change power head.