INSTALLATION AND COMMISSIONING

This appliance must be earthed.
An equipotential bonding terminal is provided to allow cross bonding with other
equipment.
If replacing the plug connect the terminals as follows:
Green and Yellow wire Earth
Blue wire
Brown wire
Means of isolation with at least 3mm contact separation in all poles must be
incorporated into the fixed wiring of the CO235M and CO235T. These units must be
connected by a qualified electrician (see power ratings).
The fixed wiring insulation must be protected by insulated sleeving having a
temperature rating of 60 Deg C.
Supply cords shall be oil resistant, sheathed flexible cable not lighter than ordinary
polychloroprene or equivalent elastomer sheathed cord (code 60245 IEC 57)
Install this appliance on a level surface ensuring all vents are unobstructed. Any
partitions, walls or furniture must be of non-combustible material. Minimum
distances A 200mm B 1000mm – see Fig 1. Leave 100mm for services.
An air filter will need occasional access. (See Fig 3 for position).
The water supply pressure must be from 2 - 6 bar (200kPa-600kPa).
Lincat recommend that a water filter should be installed.
Refer to Lincat's website for the recommended option
IS 731 ECN 4421
E
Neutral N
Live
L
Page 5 of 15