Lighting of Appliance Shut Down of Appliance Preparation for Use Maintenance of the Oven Range SERVICING 7-10 • General Routine Servicing Component Replacement Spares List TROUBLESHOOTING • TECHNICAL SPECIFICATION • SERVICE • Contact Information Lincat Service Department Conditions of Guarantee...
Part No. IS08 ECN 2339 FOREWORD Thank you for buying this Lincat product, which we hope, will give you years of trouble free service. Ensuring that you receive the maximum benefit from your new appliance, please take the time to read these instructions carefully, following any directions given.
All operators must know how to safely operate, light and shutdown the appliance. Although all Lincat oven ranges are operationally checked during manufacture, commissioning should include an operational check of all controls.
WARNING: Failure to check and set the oven low flame setting may initiate an un-necessary service call due to the oven burner "going out". HEAT INPUT. The total nominal gross heat input for the appliances are as follows: - Model SLR6 Butane gas 17.2 kW Natural gas 20.1 kW...
The enamel base tray and shelves can be removed from the oven for cleaning. Standard domestic de-greasing detergents are suitable for the cleaning of the oven liners. For heavy, stubborn, deposits a de-greasing agent ‘CARBON-OFF’ is available from Lincat upon request.
Part No. IS08 ECN 2339 SERVICING Gas catering equipment should be routinely serviced to ensure a long trouble-free life. With this in mind, it is recommended that a competent gas engineer service the appliances every 6 months. Please see page 13 “Service” for information on authorised service agents. GENERAL SERVICE 1.
Part No. IS08 ECN 2339 COMPONENT REPLACEMENT Note: When removing control knobs care must be taken not to lose the spring clips. Access is gained by removal of front facia panel Thermocouple From Hob 1. Loosen the retaining nut in the burner. 2.
Page 9
Part No. IS08 ECN 2339 COMPONENT REPLACEMENT continued. Hob Valves 1. Disconnected the gas inlet pipe from the valve. 2. Disconnect the thermocouple from the valve. 3. Loosen the valve retaining screw. 4. Replace the valve ensuring sealing washer is between the valve and the manifold. 5.
Part No. IS08 ECN 2339 SPARES LIST The following components are listed with the Lincat reference number followed by a brief description. BU35 ...Hob burner body (Note: The BU35 burner is fitted with a JE39 injector as standard) BU36 ...Burner cap BU78 ...Oven burner (SLR9)
If you know the number of the part in question, please quote this information also. Lincat reserve the right to carry out any work under warranty during normal working hours, i.e. Monday to Friday, 8.30 a.m. - 5.30 p.m.
Need help?
Do you have a question about the SLR6 and is the answer not in the manual?