Warnings And Precautions; Checklist Of Enclosures; Technical Data - Lincat CO133M Installation, Operating And Servicing Instructions

Convector
Table of Contents

Advertisement

WARNINGS AND PRECAUTIONS

This appliance must be installed, commissioned and serviced by a qualified person
in accordance with national and local regulations in force in the country of
installation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified person.
Ensure that the plug/socket is accessible at all times.
Strip plastic coating and clean the appliance before use.
During operation parts may become hot - avoid accidental contact.
Disconnect this appliance before servicing, maintenance or cleaning.
CHECK LIST OF ENCLOSURES
Instructions Manual
Shelves (2 off CO223M, CO223T).
Shelves (3 off CO133M, CO133T, CO235M, CO235T).
Water connection hose (CO133T, CO223T, CO235T).

TECHNICAL DATA

Model
Supply
CO133M
1P+N+E, 50-60 HZ
CO133T
1P+N+E, 50-60 HZ
CO223M
1P+N+E, 50-60 HZ
CO223T
1P+N+E, 50-60 HZ
1P+N+E, 50-60 HZ
CO235M
3P+N+E, 50-60 HZ
1P+N+E, 50-60 HZ
CO235T
3P+N+E, 50-60 HZ
IS 731 ECN 4421
Rating
Capacity
3 x 2/3GN
3.0kW
3 x 400x300
3 x 460 x 330
3 x 2/3GN
3.0kW
3 x 400x300
3 x 460 x 330
2 x 1/1GN
3.0kW
2 x 660x460
2 x 600 x 400
2 x 1/1GN
3.0kW
2 x 660x460
2 x 600 x 400
3 x 1/1GN
4.8kW
3 x 660x460
3 x 600 x 400
3 x 1/1GN
4.8kW
3 x 660x460
3 x 600 x 400
Page 3 of 15
Tray
Weight
Spacing
(kg)
80
55
80
55
110
70
110
70
90
70.5
90
70.5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Co223mCo133tCo235mCo223tCo235t

Table of Contents