Dantherm CDF 35 Service Manual
Hide thumbs Also See for CDF 35:

Advertisement

Quick Links

CDF 35 / 45
Service manual
Rev. 2.3
en
1

Advertisement

Table of Contents
loading

Summary of Contents for Dantherm CDF 35

  • Page 1 CDF 35 / 45 Service manual Rev. 2.3...
  • Page 2: Table Of Contents

    Mounting and installation guide Service guide Fault finding guide Technical data Service agreement Kølekredsløb/Cooling Circuit/Kältekreislauf/Circuit frigorifique/Circuito frigorifero Eldiagram/Wiring diagram/Schaltplan/Schéma électrique/Schema elet- trico, CDF 35/35T Eldiagram/Wiring diagram/Schaltplan/Schéma électrique/Schema elet- trico, CDF 45/45T Ordforklaring/Legend/Legende/Légende/Legenda Målskitser/Dimensional outlines/Maßskizzen/Croquis coté/Schema dimensionale Reservedele/Spare parts/Ersatzteile/Pièces de rechange/Parti di ricambio...
  • Page 3: General Information

    Copying of this service manual, or part of it, is forbidden without prior written permis- sion from Dantherm A/S. Reservations Dantherm A/S reserves the right to make changes and improvements to the product and the service manual at any time without prior notice or obligation. EC-Declaration of...
  • Page 4: Product- And Functional Description

    Product- and functional description Introduction This section will give you a description of the CDF 35/45 and its functionality. Functional CDF 35/45 are working in accordance with the condensation principle. The humid air is description drawn into the unit by a fan. When passing through the evaporator the air is cooled down to below dew point and water vapour is condensed into water, which is drained away.
  • Page 5 Product- and functional description, continued Built in hygrostat, If you want to set the hygrostat lower than 60 %RH, turn the adjusting screw clockwise. continued We recommend installing an external hygrostat if you want to change/adjust the setting of relative humidity very often. Connection of Connect an external hygrostat by uncoupling the built-in hygrostat from the terminals external hygrostat...
  • Page 6 Product- and functional description, continued Display indications, Part Function continued  Defrosting The LEDs 4 and 5 light up during defrosting of the mode – the evaporator. In defrosting mode the compressor is evaporator is working and the fan is stopped. When the evaporator being de- sensor has registered a temperature higher than 5 °C frosted...
  • Page 7: Mounting And Installation Guide

    NOTE Dantherm Air Handling recommends a minimum distance between dehumidifier and ceiling and dehumidifier and floor of 225 mm. The dimensions indicate the placing of the wall suspension bar.
  • Page 8: Service Guide

    Service guide Access to the CDF 35/45 CDF 35T/45T control Remove the front panel by screwing off Open the unit by removing the screws (4) two screws on top of the dehumidifier. Lift on the front of the unit, i.e. opposite to the front panel vertically upwards and the unit’s duct openings.
  • Page 9: Fault Finding Guide

    More help If you cannot find the reason for the fault, switch off the unit immediately in order to prevent further damage. Contact a service technician or a Dantherm representative.
  • Page 10: Technical Data

    Technical data General data The table shows the dehumidifier’s general technical data: CDF 35/35T CDF 45/45T Working area, humidity 60 %RF 40-100 Working area, temperature °C 3-30 Power supply V/Hz 230/50 Max. ampere consumption Max. power consumption 0.70 Air volume at max. external...
  • Page 11: Service Agreement

    Hotline The After Sales Support Department of Dantherm A/S is ready to help you in case of a problem. To be able to offer quick and efficient help, please have the following information ready when contacting Dantherm A/S: ...
  • Page 12: Kølekredsløb/Cooling Circuit/Kältekreislauf/Circuit Frigorifique/Circuito

    Kølekredsløb/Cooling Circuit/Kältekreislauf/Circuit frigorif- ique/Circuito frigorifero Illustration CDF 35/35T CDF 45/45T Nr./No.  Kompressor compressor Kompressor  Fordamper evaporator Verdampfer  Luftkølet kondensator air-cooled condenser luftgekühlter Kondensator  Termo ekspansions- thermostatic expansion thermostatisches ventil valve Expansionsventil  Væskebeholder/- receiver/liquid line drier Receiver/Trockenfilter tørrefilter...
  • Page 13: Eldiagram/Wiring Diagram/Schaltplan/Schéma Électrique/Schema Elet

    Eldiagram/Wiring diagram/Schaltplan/Schéma électrique/Schema elettrico, CDF 35/35T Diagram, CDF 35/35T, 1 x 230 V/50 Hz...
  • Page 14: Eldiagram/Wiring Diagram/Schaltplan/Schéma Électrique/Schema Elet

    Eldiagram/Wiring diagram/Schaltplan/Schéma électrique/Schema elettrico, CDF 45/45T Diagram, CDF 45/45T, 1 x 230 V/50 Hz...
  • Page 15: Ordforklaring/Legend/Legende/Légende/Legenda

    Ordforklaring/Legend/Legende/Légende/Legenda Ordforklaring til el-diagram Legend for wiring diagram Legende für Schaltplan Légende du schéma électrique Legenda schema elettrico Pos. Beskrivelse Designation Beschreibung Désignation Descrizione R3.1 Kondensator- Condenser Kondensator- Sonde du Sensore del føler sensor fühler condenseur condensatore R3.2 Fordamperfø- Evaporator Verdampfer- Sonde Sensore...
  • Page 16: Målskitser/Dimensional Outlines/Maßskizzen/Croquis Coté/Schema

    Målskitser/Dimensional outlines/Maßskizzen/Croquis coté/Schema dimensionale Model CDF 35T 387 mm 887 mm 130 x 410 mm CDF 45T 692 mm 1192 mm 130 x 720 mm Kanalåbning i muren • Duct opening in the wall • Kanalöffnung im Mauer • Ouverture de gaine dans le mur • Apertura nel muro per passaggio canali Fortsættes/continued overleaf/fortsetzt/Suite à...
  • Page 17 Målskitser/Dimensional outlines/Maßskizzen/Croquis coté/Schema dimensionale, continued Målene angiver placeringen af vægbeslaget The dimensions indicate the placing of the suspension bar Die Dimensionen zeigen die Plazierung der Wandkonsole an Les dimensions indiquent la position de la barre d’ancrage Le misure indicano la posizione della staffa di ancoraggio...
  • Page 18: Reservedele/Spare Parts/Ersatzteile/Pièces De Rechange/Parti Di

    Reservedele/Spare parts/Ersatzteile/Pièces de rechange/Parti di ricambio Illustration CDF 35/45 1 × 230 V/50 Hz Fortsættes/continued overleaf/fortsetzt/Suite à la page suivante/continua alla pagina seguente...
  • Page 19 Condensate tray, CDF 35 293618 Drypbakke, CDF 45 Condensate tray, CDF 45 293662 Front, kpl., CDF 35 Front cover panel cpl., CDF 35 293666 Front, kpl., CDF 45 Front cover panel cpl., CDF 45 033917 Skilt, CDF 35 Label, CDF 35...
  • Page 20 2 polet klemme Bipolar terminal 602444 Driftkondensator Capacitor 293635 607232 Receiver/tørre¬filter Receiver/liquid line drier 603969 Termoventil, CDF 35 Thermostatic valve, CDF 35 046171 Termoventil, CDF 45 Thermostatic valve, CDF 45 25/26 032675 Føler, 2600mm Sensor, 2600 mm 605470 Magnetventil Solenoid valve...
  • Page 21 +(0) 121 133 70 infodk@dantherm.com dantherm.no@dantherm.com infose@dantherm.com www.dantherm.com www.dantherm.no www.dantherm.se Dantherm Air Handling (Suzhou) Ltd. Dantherm Limited Dantherm Air Handling Inc. Bldg#9, No.855 Zhu Jiang Rd., 12 Windmill Business Park 110 Corporate Drive, Suite K Suzhou New District, Jiangsu Windmill Road, Clevedon...
  • Page 22 Dantherm Air Handling A/S Marienlystvej 65 7800 Skive Denmark www.dantherm.com service@dantherm.com...

This manual is also suitable for:

Cdf 45Cdf 45tCdf 35t

Table of Contents