Vega VEGABAR 82 Quick Setup Manual

Vega VEGABAR 82 Quick Setup Manual

Pressure transmitter with ceramic measuring cell
Hide thumbs Also See for VEGABAR 82:

Advertisement

Quick setup guide
Pressure transmitter with ceramic
measuring cell
VEGABAR 82
Slave sensor for electronic differential pres-
sure
With SIL qualification
Document ID: 48051

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VEGABAR 82 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vega VEGABAR 82

  • Page 1 Quick setup guide Pressure transmitter with ceramic measuring cell VEGABAR 82 Slave sensor for electronic differential pres- sure With SIL qualification Document ID: 48051...
  • Page 2: Table Of Contents

    Operating Instructions Manual as well as the Safety Manual that comes with instruments with SIL qualification. These manuals are available in the download area of "www.vega.com". Operating instructions VEGABAR 82 - Slave sensor for elec- tronic differential pressure with SIL qualification: Document-ID 48046 Safety Manual VEGABAR series 80 - Two-wire 4 …...
  • Page 3: For Your Safety

    During work on and with the device, the required personal protective equipment must always be worn. Appropriate use VEGABAR 82 is a slave sensor for electronic differential pressure measurement. You can find detailed information about the area of application in chapter "Product description".
  • Page 4: Eu Conformity

    (see chapter "Technical Data"). In addition, a temperature derating of the process fitting, e. g. with flanges, can limit the permissible process pressure range according to the respective standard. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 5: Product Description

    Alternatively, you can access the data via your smartphone: • Download the VEGA Tools app from the "Apple App Store" or the "Google Play Store" • Scan the Data Matrix code on the type label of the instrument or •...
  • Page 6: Mounting

    Instruments with absolute pressure Combination Master - Slave In principle, any sensor combination within the instrument series is allowed. The following requirements must be fulfilled: • Configuration, Master sensor suitable for electronic differential pressure VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 7 Static pressure: 0.8 bar Differential pressure on orifice: 50 mbar = 0.050 bar Total pressure: 0.8 bar + 0.05 bar = 0.85 bar Instrument selection Nominal measuring range Master: 1 bar VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 8 Slave (static or superimposed pressure) are output by the sensor. Depending on the instrument version, output as 4 … 20 mA signal or digitally via HART, Profibus PA or Foundation Fieldbus. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 9: Connecting To Power Supply

    Fig. 3: Connection steps 5 and 6 5. Insert the wire ends into the terminals according to the wiring plan 6. Check the hold of the wires in the terminals by lightly pulling on them VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 10: Single Chamber Housing

    Ground terminal for connection of the cable screening Connect shielding here. Connect ground terminal on the outside of the hous- ing to ground as prescribed. The two terminals are galvanically connected. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 11: Connection Example

    Connection between master and sensor is carried out according to the table: Master sensor Slave sensor Terminal 5 Terminal 5 Terminal 6 Terminal 6 Terminal 7 Terminal 7 Terminal 8 Terminal 8 VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 12: Set Up With The Display And Adjustment Module

    The display and adjustment module is powered by the sensor, an ad- ditional connection is not necessary. Fig. 6: Installing the display and adjustment module in the electronics compart- ment of the single chamber housing VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 13: Parameter Adjustment

    For each parameter change you have to enter the PIN of the instru- ment. In delivery status, the PIN is "0000". Change parameters You can find a description below the respective parameter. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 14 4. Depending on the application, carry out the adjustment e.g. in the menu items "Min. adjustment" and "Max. adjustment". Parameterization example VEGABAR 82 always measures pressure independently of the pro- cess variable selected in the menu item "Application". To output the selected process variable correctly, an allocation of the output signal to 0 % and 100 % must be carried out (adjustment).
  • Page 15 Afterwards you confirm that the serial number of your instrument was carried over correctly. This is used to check device communication. 4. Verify parameters Confirm the modified values one after the other. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 16: Menu Overview

    ≤ 3.6 mA Current output - Min./ 3.8 mA Max. 20.5 mA Lock adjust- Last setting ment (SIL) Display Menu item Default setting Menu language Order-specific Displayed value 1 Current output in % VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 17 0.00 % correspond to 0.00 m 100.00 %, 1 m Info Menu item Parameter Device name VEGABAR 82 Instrument version Hardware and software version Factory calibration Date date Sensor characteristics Order-specific characteristics VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 18: Supplement

    < 0.05 Ω/m (0.015 Ω/ft) Voltage supply for the complete system through Master Operating voltage Ʋ U 12 V DC B min IP 66/IP 68 (0.2 bar), only with absolute pressure. VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 19 6 Supplement Ʋ U with lighting switched on 16 V DC B min Ʋ U Depending on signal output and version of the master B max sensor VEGABAR 82 • Slave sensor for electronic differential pressure...
  • Page 20: Information

    Subject to change without prior notice © VEGA Grieshaber KG, Schiltach/Germany 2019 VEGA Grieshaber KG Phone +49 7836 50-0 Fax +49 7836 50-201 Am Hohenstein 113 E-mail: info.de@vega.com...

Table of Contents